ISO 16017-1:2000
Indoor, ambiant and workplace air - Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography - Part 1: Pumped sampling

Standard No.
ISO 16017-1:2000
Release Date
2000
Published By
International Organization for Standardization (ISO)
Latest
ISO 16017-1:2000
Scope
This part of ISO 16017 gives general guidance for the sampling and analysis of volatile organic compounds (VOCs) in air. It is applicable to ambient, indoor and workplace atmospheres and the assessment of emissions from materials in small- or full-scale test chambers. This part of ISO 16017 is appropriate for a wide range of VOCs, including hydrocarbons, halogenated hydro-carbons, esters, glycol ethers, ketones and alcohols. A number of sorbents are recommended for the sampling of these VOCs, each sorbent having a different range of applicability. Very polar compounds will generally require derivatization, very low boiling compounds will only be partially retained by the sorbents, depending on ambient temperature, and can only be estimated qualitatively. Semi-volatile compounds will be fully retained by the sorbents, but may only be partially recovered. Compounds for which this part of ISO 16017 has been tested are given in tables. This part of ISO 16017 may be applicable to compounds not listed, but in these cases it is advisable to use a back-up tube containing the same or a stronger sorbent. This part of ISO 16017 is applicable to the measurement of airborne vapours of VOCs in a concentration range of approximately 0,5 μg/ m to 100 mg/m individual compound. The upper limit of the useful range is set by the sorptive capacity of the sorbent used and by the linear dynamic range of the gas chromatograph column and detector or by the sample-splitting capability of the analytical instrumentation used. The sorptive capacity is measured as a breakthrough volume of air, which determines the maximum air volume that shall not be exceeded when sampling. The lower limit of the useful range depends on the noise level of the detector and on blank levels of analyte and/or interfering artefacts on the sorbent tubes. Artefacts are typically sub-nanogram for well-conditioned Tenax GR and carbonaceous sorbents such as Carbopack/Carbotrap type materials, carbonized molecular sieves and molecular sieves such as Spherocarb, or pure charcoal; at low nanogram levels for Tenax TA and at 5 ng to 50 ng levels for other porous polymers such as Chromosorbs and Porapaks. Sensitivity is typically limited to 0,5 μg/m for 10-litre air samples with this latter group of sorbents because of their inherent high background. The procedure specified in this part of ISO 16017 is applicable to low flowrate personal sampling pumps and gives a time-weighted average result. It is not applicable to the measurement of instantaneous or short-term fluctuations in concentration. note: 1) The sorbents listed in annex C and elsewhere in this International Standard are those known to perform as specified under this part of ISO 16017. Each sorbent or product that is identified by a trademarked name is unique and has a sole manufacturer; however, they are widely available from many different suppliers. This information is given for the convenience of users of this part of ISO 16017 and does not constitute an endorsement by ISO of the product named. Equivalent products may be used if they can be shown to lead to the same results.

ISO 16017-1:2000 Referenced Document

  • EN 1076:1997 Workplace Atmospheres - Pumped Sorbent Tubes for the Determination of Gases and Vapours - Requirements and Test Methods
  • ISO 5725-1:1994 Accuracy (trueness and precision) of measurement methods and results - Part 1: General principles and definitions
  • ISO 5725-2:1994 Accuracy (trueness and precision) of measurement methods and results - Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method
  • ISO 6141:2000 Gas analysis - Requirements for certificates for calibration gases and gas mixtures
  • ISO 6145-1:1986 Gas analysis; Preparation of calibration gas mixtures; Dynamic volumetric methods; Part 1 : Methods of calibration
  • ISO 6145-3:1986 Gas analysis — Preparation of calibration gas mixtures — Dynamic volumetric methods — Part 3: Periodic injections into a flowing gas stream
  • ISO 6145-4:1986 Gas analysis; Preparation of calibration gas mixtures; Dynamic volumetric methods; Part 4 : Continuous injection method
  • ISO 6145-5 Gas analysis - Preparation of calibration gas mixtures using dynamic volumetric methods - Part 5: Capillary calibration devices*2009-11-01 Update
  • ISO 6145-6 Gas analysis - Preparation of calibration gas mixtures using dynamic methods - Part 6: Critical flow orifices*2017-07-01 Update
  • ISO 6349:1979 Gas analysis — Preparation of calibration gas mixtures — Permeation method

ISO 16017-1:2000 history

  • 2000 ISO 16017-1:2000 Indoor, ambiant and workplace air - Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography - Part 1: Pumped sampling
Indoor, ambiant and workplace air - Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography - Part 1: Pumped sampling