BS EN 12442-1:2000
Animal tissues and their derivatives utilized in the manufacture of medical devices - Analysis and management of risk

Standard No.
BS EN 12442-1:2000
Release Date
2000
Published By
British Standards Institution (BSI)
Status
 2008-02
Replace By
BS EN ISO 22442-1:2007
BS EN ISO 22442-1:2008
Latest
BS EN ISO 22442-1:2015
Replace
96/562030 DC-1996
Scope
1 This Part of EN 12442 applies to medical devices (excluding in-vitro diagnostic medical devices) manufactured utilizing animal tissue or products derived from animal tissue, which are non-viable or have been rendered non-viable. It specifies, in conjunction with EN 1441, a procedure to investigate, using available information, the safety of such devices by identifying hazards and estimating the risks associated with the device (risk analysis). 2 This Part of EN 12442 is intended to provide requirements and guidance on risk analysis related to the typical hazards of medical devices manufactured utilizing animal tissues or derivatives such as a) contamination by bacteria, moulds or yeasts; b) contamination by viruses or transmissible agents such as pathogenic entities, or agents causing spongiform encephalopathies, prions and similar entities (e.g. BSE, scrapie); c) undesired pyrogenic, immunological or toxicological reactions. 3 This Part of EN 12442 does not stipulate levels of acceptability which, because they are determined by a multiplicity of factors, cannot be set down in such a standard. 4 In addition, this Part of EN 12442 is intended to provide requirements and guidance on risk management. 5 This Part of EN 12442 does not cover the utilization of human tissues in medical devices. NOTE: There are materials which do not fall under the scope of this standard because these are not derived from animals. In this standard a specific definition of animal has been given. 6 This Part of EN 12442 does not describe a quality assurance system for the control of all stages of manufacture. NOTE: Attention is drawn to the standards for quality systems (see EN ISO 9001 and EN 46001 or EN ISO 9002 and EN 46002) which relate to all stages of manufacture. It is not a requirement of this standard to have a complete quality system during manufacture but certain elements of such a system are required. 7 The principles of this Part of EN 12442 may also be applied by analogy to medical devices manufactured utilizing material derived from a non-vertebrate organism, in cases where the risks addressed in this standard are relevant.

BS EN 12442-1:2000 history

  • 2015 BS EN ISO 22442-1:2015 Medical devices utilizing animal tissues and their derivatives. Application of risk management
  • 0000 BS EN ISO 22442-1:2007
  • 2000 BS EN 12442-1:2000 Animal tissues and their derivatives utilized in the manufacture of medical devices - Analysis and management of risk
Animal tissues and their derivatives utilized in the manufacture of medical devices - Analysis and management of risk