IEC 61243-2:2000
Live working - Voltage detectors - Part 2: Resistive type to be used for voltages of 1 kV to 36 kV a.c.

Standard No.
IEC 61243-2:2000
Release Date
2000
Published By
International Electrotechnical Commission (IEC)
Status
Replace By
IEC 61243-2:1995/COR3:2000
Latest
IEC 61243-2:1995/AMD2:2002
Scope
This part of IEC 61243 is applicable to portable voltage detectors with or without a built-in power source to be used on electrical systems for voltages of 1 kV to 36 kV a.c., and frequencies from 15 Hz to 60 Hz. This part applies only to resistive voltage detectors used in contact with the part to be tested, as a single unit or as a separate device completed by an adaptable insulating pole covered in IEC 60855 or IEC 61235. Other types of voltage detectors are not covered by this part of standard. Capacitive voltage detectors are covered in IEC 61243-1. The upper voltage limit is in accordance with the tests described in this part of IEC 61243. Some restrictions on their use are applicable in the case of factory-assembled switchgear and on overhead systems of electrified railways (see annex B). NOTE 1 Except when otherwise specified, all the voltages defined in this standard refer to phase-to-phase voltages of three-phase systems. Resistive detectors may be used in other than three-phase systems, but the applicable phase-to-phase or phase-to-earth (ground) voltage shall be used to determine the operating voltage. NOTE 2 Although this standard does not cover d.c. voltage detectors, some detectors may respond to d.c. voltage.

IEC 61243-2:2000 history

  • 2002 IEC 61243-2:1995/AMD2:2002 Live working - Part 2: Resistive type to be used for voltages of 1 kV to 36 kV a.c.; Amendment 2
  • 2002 IEC 61243-2:2002 Live working - Voltage detectors - Part 2: Resistive type to be used for voltages of 1 kV to 36 kV a.c.
  • 2000 IEC 61243-2:1995/COR3:2000 Live working - Voltage detectors - Part 2: Resistive type to be used for voltages of 1 kV to 36 kV a.c.; Corrigendum 3
  • 2000 IEC 61243-2:2000 Live working - Voltage detectors - Part 2: Resistive type to be used for voltages of 1 kV to 36 kV a.c.
  • 1999 IEC 61243-2:1995/COR2:1999 Live working - Voltage detectors - Part 2: Resistive type to be used for voltages of 1 kV to 36 kV a.c.; Corrigendum 2
  • 2000 IEC 61243-2:1995/AMD1:1999 Live working - Voltage detectors - Part 2: Resistive type to be used for voltages of 1 kV to 36 kV a.c.
  • 1996 IEC 61243-2:1995/COR1:1996 Live Working - Voltage Detectors - Part 2: Resistive Type to Be Used for Voltages of 1 kV to 36 kV (Edition 1.0)
  • 1995 IEC 61243-2:1995 Live working - Voltage detectors - Part 2: Resistive type to be used for voltages of 1 kV to 36 kV a.c.



Copyright ©2024 All Rights Reserved