Scope
This part of GB/T 7672 specifies the requirements for temperature index 180, impregnated glass fiber clad copper round wire and impregnated paint glass fiber clad enamelled copper round wire, grade 1 or 2 paint film thickness. The impregnating paint may be, for example, polyester or polyesterimide resin paint. Note: For this type of winding wire, the thermal shock test is not applicable, and the thermal shock temperature cannot be determined. Therefore, it is not possible to specify classes based on temperature index and thermal shock temperature requirements. Enameled wire should be based on one of the following standards: GB/T 6109.5-2008, GB/T 6109.20-2008 or GB/T 6109.22-2008, and should be determined through negotiation between the supply and demand parties. The temperature index of glass fiber clad copper round winding wire depends on the type of impregnating varnish used. The impregnating paint for impregnated glass filaments should have a minimum temperature index of 180. The glass fiber cladding can be: a) Single glass fiber cladding; b) Double glass fiber cladding, with the two layers of glass fiber wrapping in opposite directions. The nominal diameter range of conductors in this section is as follows:  ——Double glass filaments (GL2) wrapped on bare conductors: from 0.500mm to and including 5.000mm;  ——Glass filaments wrapped on enameled wires with grade 1 paint film thickness (Grade 1 GL1 and Grade 1 GL2): from 0.500mm to and including 1.600mm;  ——Glass filaments wrapped on enameled wire with grade 2 paint film thickness (Grade 1 GL1 and Grade 1 GL2): from 0.500mm to and including 5.000mm; Nominal conductor The diameter is specified in Chapter 4 of GB/T 7672.21-2008.

IEC 60317-49:1999 history

  • 2013 IEC 60317-49:2012/COR1:2013 Specifications for particular types of winding wires – Part 49: Glass-fibre wound high temperature resin or varnish impregnated@ bare or enamelled round copper wire@ temperature index 180 (Edition 2.0)
  • 2012 IEC 60317-49:2012 Spécifications pour types particuliers de fils de bobinage – Partie 49: Fil de section circulaire en cuivre nu ou émaillé@ recouvert d'un guipage de fibres de verre haute température imprégnées de résine ou de vernis@ indice de température 180 (Edition 2.
  • 1999 IEC 60317-49:1999 Specifications for particular types of winding wires - Part 49: Glass-fibre wound resin or varnish impregnated, bare or enamelled round copper wire, temperature index 180