IEC 61000-4-16:1998
Electromagnetic compatibility (EMC) - Part 4-16: Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kKz

Standard No.
IEC 61000-4-16:1998
Release Date
1998
Published By
International Electrotechnical Commission (IEC)
Status
 2001-08
Replace By
IEC 61000-4-16:1998/AMD1:2001
Latest
IEC 61000-4-16:2015 RLV
Replace
IEC 77A/201/FDIS:1997
Scope
This part of IEC 61000 relates to the immunity requirements and test methods for electrical and electronic equipment to conducted, common mode disturbances in the range de. to 150 kHz. The object of this standard is to establish a common and reproducible basis for testing electrical and electronic equipment with the application of common mode disturbances to power supply, control, signal and communication ports. This standard defines - test voltage and current waveform; - range of test levels; - test equipment; - test set-up; - test procedures. For some types of ports, for example ports intended to be used with highly balanced lines, additional test provisions may be established by product committee specifications. The test is intended to demonstrate the immunity of electrical and electronic equipment when subjected to conducted, common mode disturbances such as those originating from power line currents and return leakage currents in the earthing/grounding system. The disturbances produced by 400 Hz mains systems are not included in the scope of this standard. Actual interference due to these disturbance phenomena is relatively rare, except in industrial plants. Product Committees should therefore consider whether there is a justification for applying this standard in their Product/Product Family standards (see also clause 3). This test is not relevant for equipment ports intended to be connected to short cables, having a length less than 20 m or less. The immunity to harmonics and interharmonics, including mains signalling, on a.c. power ports (in differential mode) is not included in the scope of this standard and is covered by IEC 61000-4-13. The immunity to conducted disturbances generated by intentional radio-frequency transmitters is not included in the scope of this standard and is covered by IEC 61000-4-6. Some ITU-T Recommendations, e.g. K17, K20 and K21, establish similar methods for testing the resistibility of equipment; however, they are dedicated to telecommunication ports and deal with power induction at frequency of the a.c. mains or electric railways. Product Committees are advised to consider the Recommendations above, as far as applicable, in preparing their product standards.

IEC 61000-4-16:1998 history

  • 0000 IEC 61000-4-16:2015 RLV
  • 2011 IEC 61000-4-16:2011 Electromagnetic compatibility (EMC) - Part 4-16: Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kKz
  • 2009 IEC 61000-4-16:1998/AMD2:2009 Electromagnetic compatibility (EMC) - Part 4-16: Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz; Amendment 2
  • 2002 IEC 61000-4-16:2002 Electromagnetic compatibility (EMC) - Part 4-16: Testing and measurement techniques; Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kKz
  • 2001 IEC 61000-4-16:1998/AMD1:2001 Electromagnetic compatibility (EMC) - Part 4-16: Testing and measurement techniques; Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz; Amendment 1
  • 1998 IEC 61000-4-16:1998 Electromagnetic compatibility (EMC) - Part 4-16: Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kKz



Copyright ©2024 All Rights Reserved