IEEE C62.22-1997
Guide for the Application of Metal-Oxide Surge Arresters for Alternating-Current Systems

Standard No.
IEEE C62.22-1997
Release Date
1997
Published By
IEEE - The Institute of Electrical and Electronics Engineers@ Inc.
Status
Replace By
IEEE C62.22-2009
Latest
IEEE C62.22-2009
Scope
Foreword?This guide presents the suggested application methods for using metal-oxide surge arresters when applied to ac power systems. This guide was written for arresters with and without gaps. Soon to be published IEC 99-5 is a similar standard used in the international community for arresters without gaps.ScopeThis guide covers the application of metal-oxide surge arresters (see IEEE Std C62.11-1993) to safeguard electric power equipment against the hazards of abnormally high voltage surges of various origins. Such overvoltages may cause flashovers and serious damage to equipment and thereby jeopardize the supply of power to users. It is essential to prevent this by the proper coordination of surge-protective devices with the insulation strength of the protected equipment.This application guide does not cover the application of low-voltage surge protective devices below 1000 V ac. However@ it references these devices when applied to the secondary of a transformer since they are part of the transformer protection.The subject is broad@ with many ramifications@ and it requires a volume of considerable bulk to explain all possible cases in detail. Clause 5 of this guide covers the basic cases for stations used to supply and switch electric power transmission@ subtransmission@ or distribution feeders. Information is included in Clause 6 on application of arresters for protection of overhead and underground distribution systems@ all distribution transformers@ and other electric distribution equipment.Step-by-step directions toward proper solutions for various applications are provided. In many cases@ the prescribed steps are adequate. More complex and special situations requiring study by experienced engineers are described@ but specific solutions may not be given. These procedures are based on theoretical studies@ test results@ and experience.

IEEE C62.22-1997 history

  • 1970 IEEE C62.22-2009 IEEE Guide for the Application of Metal-Oxide Surge Arresters for Alternating-Current Systems
  • 1997 IEEE C62.22-1997 Guide for the Application of Metal-Oxide Surge Arresters for Alternating-Current Systems
  • 1991 IEEE C62.22-1991 Guide for the Application of Metal-Oxide Surge Arresters for Alternating-Current Systems



Copyright ©2024 All Rights Reserved