UL 1711 BULLETINS-2002
UL Standard for Safety Amplifiers for Fire Protective Signaling Systems (07/10/2002 (8p); 07/01/2002 (234p))

Standard No.
UL 1711 BULLETINS-2002
Release Date
2002
Published By
Underwriters Laboratories (UL)
Status
 2008-10
Replace By
UL 1711 BULLETIN-2003
Latest
UL 1711 BULLETIN-2017
Scope
These requirements cover discrete electrical control units and accessories for fire alarm systems to be employed in accordance with the following National Fire Protection Association (NFPA) Standards: a) NFPA 12@ Carbon Dioxide Extinguishing Systems; b) NFPA 12A@ Halon 1301 Fire Extinguishing Systems; c) NFPA 13@ Installation of Sprinkler Systems; d) NFPA 15@ Water Spray Fixed Systems for Fire Protection; e) NFPA 16@ Installation of Foam-Water Sprinkler and Foam-Water Spray Systems; f) NFPA 17@ Dry Chemical Extinguishing Systems; g) NFPA 17A@ Wet Chemical Extinguishing Systems; h) NFPA 70@ National Electrical Code; i) NFPA 72@ Signaling Systems for the Protection of Life and Property; j) NFPA 92A@ Recommended Practice for Smoke-Control Systems; k) NFPA 92B@ Guide for Smoke Management Systems in Malls@ Atria@ and Large Areas; and l) NFPA 2001@ Clean Agent Fire Extinguishing Systems. The products covered by this standard are intended to be used in combination with other appliances and devices to form a commercial fire alarm system. These products provide all monitoring@ control@ and indicating functions of the system. An installation document(s) provided with the product describes the various products needed to form a fire alarm system and their intended use and installation. These requirements do not cover manual boxes@ automatic fire detectors@ automatic transmitters@ or other initiating devices; nor do they cover notification appliances not provided as part of the product.

UL 1711 BULLETINS-2002 history

  • 2017 UL 1711 BULLETIN-2017 UL Standard for Safety Amplifiers for Fire Protective Signaling Systems
  • 2008 UL 1711 BULLETIN-2008 UL Standard for Safety Amplifiers for Fire Protective Signaling Systems
  • 2006 UL 1711-2006 UL Standard for Safety Amplifiers for Fire Protective Signaling Systems (Fourth Edition)
  • 2005 UL 1711 BULLETIN-2005 UL Standard for Safety Amplifiers for Fire Protective Signaling Systems
  • 2003 UL 1711 BULLETINS-2003 4/9/2003 (108p)
  • 2003 UL 1711 BULLETIN-2003 UL Standard for Safety Amplifiers for Fire Protective Signaling Systems
  • 2002 UL 1711 BULLETINS-2002 UL Standard for Safety Amplifiers for Fire Protective Signaling Systems (07/10/2002 (8p); 07/01/2002 (234p))
  • 2001 UL 1711 BULLETIN-2001 UL Standard for Safety Amplifiers for Fire Protective Signaling Systems
  • 1999 UL 1711-1999 Amplifiers for fire protective signaling systems
  • 1994 UL 1711-1994 UL Standard for Safety Amplifiers for Fire Protective Signaling Systems (Second Edition)