Technical indicators | GB6220-2009 | GB6220-2023 |
---|---|---|
Mask type | Only tight type | New open type mask and air supply hood |
Leakage rate requirement | Full mask≤0.05% | Graded control (half mask 0.5%/full mask 0.05%) |
Test items | 7 items | 11 new tests for breathing tubes, air supply tubes, etc. |
Standard 5.1.2 clearly requires that aluminum-magnesium-titanium alloy parts used in explosive environments must be coated, and manufacturers must provide risk assessment statements. A typical case shows that a petrochemical company caused an electrostatic accident due to the failure to use a coated respirator.
New flow control valve automatic locking function (5.13) to ensure that the minimum air supply of 95L/min (closed type) or 120L/min (open type) is maintained in the event of accidental adjustment. Test data shows that this design can reduce the risk of insufficient air supply caused by misoperation by 72%.
The dynamic action combination test method is adopted, including 5 working conditions such as static, turning head, and speaking, which is closer to the actual working scene. A comparative test by a certain testing agency shows that the new method can detect a leakage rate 15%-20% higher than the old standard.
Three new key tests:
- Anti-kink test: The flow attenuation of the low-pressure pipe at a right angle bend is ≤50%
- Extrusion resistance test: The medium-pressure pipe withstands a radial force of 1000N
- Heat resistance test: No failure after contact with a 130℃ hot plate for 15 minutes