UL 486D BULLETIN-2008
UL Standard for Safety Sealed Wire Connector Systems (COMMENTS DUE: NOVEMBER 15@ 2008)

Standard No.
UL 486D BULLETIN-2008
Release Date
2008
Published By
Underwriters Laboratories (UL)
Status
 2009-06
Replace By
UL 486D BULLETIN-2009
Latest
UL 486D BULLETIN-2017
Scope
The requirements in this standard cover sealed wire connector systems@ including insulating caps@ covers@ resins@ tubing@ and tapes provided with@ or for use with@ specific wire connectors. These systems are intended for wet or damp locations@ and other installations such as direct burial@ below grade@ or above grade where protected from direct exposure to sunlight. The wire connectors covered by these requirements are intended for use with copper conductor@ aluminum conductor@ or both in accordance with installations covered by the National Electrical Code@ NFPA 70; the Canadian Electrical Code@ Part I@ C22.1; and NOM 001 SEDE@ Standard for Electrical Installations.Note 1 These wire connector systems have not been evaluated for direct exposure to sunlight. Additional performance considerations to show equivalency to the connected conductors should be considered for UV exposure.Note 2 These wire connector systems may also be used indoors.These requirements also cover sealed wire connector systems intended for use with single or multiple conductor underground feeder cable@ golf course sprinkler cable@ underground low energy cable@ irrigation cable@ or other cable with insulation acceptable for direct burial@ below grade use@ or wet locations. These requirements apply to sealed wire connector systems intended for use with 30 AWG (0.05 mm2) through 2 000 kcmil (1 012 mm2) conductors with currents not exceeding the ampacity of insulated conductors rated either 75 ??(167 ?? or 90 ??(194 ?? and intended for use at 600 V or less.For products intended for use in Canada@ general requirements are given in CAN/CSA-C22.2 No. 0.

UL 486D BULLETIN-2008 history

  • 2017 UL 486D BULLETIN-2017 UL Standard for Safety Sealed Wire Connector Systems (COMMENTS DUE: August 28@ 2017)
  • 1970 UL 486D-2017 Sealed wire connector systems
  • 2015 UL 486D CRD-2015 UL Standard for Safety Sealed Wire Connector Systems - Section / Paragraph Reference: New Paragraphs 1.4@ 9.2.3.2@ and 9.2.9.2; Revised Paragraphs 9.2.3.1 and 9.2.9.1 Subject: Sealed Wire Connector Systems Rated 601 – 1500 V (Edition 5: December 12@ 2005)
  • 2015 UL 486D BULLETIN-2015 UL Standard for Safety Sealed Wire Connector Systems (COMMENTS DUE: MARCH 9@ 2015)
  • 2015 UL 486D-2015 UL Standard for Safety Sealed Wire Connector Systems (Sixth Edition)
  • 2014 UL 486D BULLETIN-2014 UL Standard for Safety Sealed Wire Connector Systems (COMMENTS DUE: JUNE 23@ 2014)
  • 2013 UL 486D CRD-2013 UL Standard for Safety Sealed Wire Connector Systems - Section / Paragraph Reference: 9.1.5 Subject: Current certification practices when testing with conductors smaller than 16 AWG (Edition 5: December 12@ 2005)
  • 2009 UL 486D BULLETIN-2009 UL Standard for Safety Sealed Wire Connector Systems (COMMENTS DUE: AUGUST 10@ 2009)
  • 2008 UL 486D BULLETIN-2008 UL Standard for Safety Sealed Wire Connector Systems (COMMENTS DUE: NOVEMBER 15@ 2008)
  • 2005 UL 486D BULLETIN-2005 UL Standard for Safety Sealed Wire Connector Systems
  • 2005 UL 486D-2005 Sealed wire connector systems
  • 1997 UL 486D-1997 Insulated wire connector systems for underground use or in damp or wet locations
  • 1993 UL 486D-1993 UL Standard for Safety Insulated Wire Connectors for Use with Underground Conductors (Third Edition; Reprint with Revisions Through and Including April 18@ 1993)



Copyright ©2024 All Rights Reserved