UL 2600-2018
UL Standard for Safety for Relocatable Structures (Second Edition)

Standard No.
UL 2600-2018
Release Date
2018
Published By
Underwriters Laboratories (UL)
Status
 2018-07
Replace By
UL 2600 BULLETIN-2018
Latest
UL 2600-2020
Scope
This standard provides the requirements for modular built relocatable temporary structures. Relocatable structures for temporary use are a form of modular construction@ built in an approved offsite facility@ designed to be transported to a location@ assembled@ and utilized. During the life of these structures they may be used in several different locations. The buildings constructed under this standard are permitted to be of combustible construction or noncombustible construction@ used singly or in combination@ This standard specifies requirements including@ but not limited to: a) National Building Code of Canada (NBC) objectives: i) safety; ii) health; and iii) fire structural protection of buildings b) identification and labeling A building regulated by this standard need not meet the requirements of the Section 9.36 of the NBC@ or the National Energy Code of Canada for Buildings (NECB) as it pertains to: a) the design and construction of the building envelope; and b) the design and construction or specification of systems and equipment for: i) lighting@ heating@ ventilating or air-conditioning; and ii) service water heating. See subsection 18.2 Insulation@ 18.3 Ventilation@ and Annex D@ D18.2. This Standard applies to: a) a one storey building i) without sleeping accommodation@ that is not more than 1 200 m2 in building area@ and if sprinklered@ is not more than 2 400 m2 in building area@ and ii) with sleeping accommodation@ that is not more than 600 m2 in building area@ and if sprinklered@ is not more than 1 200 m2 in building area@ and b) a two storey building i) without sleeping accommodation@ that is not more than 600 m2 in building area@ and if sprinklered@ is not more than 1 200 m2 in building area@ and ii) with sleeping accommodation@ that is not more than 300 m2 in building area@ and if sprinklered@ is not more than 600 m2 in building area. See 20.3 Building Cluster. A building described in Clause 1.6 is permitted to consist of one or more transportable modules specifically designed to be readily relocatable and usable without permanent foundations.

UL 2600-2018 history

  • 1970 UL 2600-2020 UL Standard for Safety for Relocatable Structures
  • 2019 UL 2600-2019 Relocatable Buildings
  • 2018 UL 2600 BULLETIN-2018 UL Standard for Safety for Relocatable Structures
  • 2018 UL 2600-2018 UL Standard for Safety for Relocatable Structures (Second Edition)
  • 2017 UL 2600 BULLETIN-2017 UL Standard for Safety for Relocatable Structures (COMMENTS DUE: August 2@ 2017)
  • 2017 UL 2600-2017 UL Standard for Safety for Relocatable Structures (First Edition)
  • 2016 UL 2600 BULLETIN-2016 UL Standard for Safety Relocatable Structures (COMMENTS DUE: January 6@ 2016)