1.1 This test method covers the nondestructive measurement of the dry film thickness of electrically nonconductive coatings applied over a nonferrous metal base using commercially available eddy current instruments. This test method is intended to supplement manufacturers’ instructions for the manual operation of the gages, and is not intended to replace them.
1.2 This test method is not applicable to coatings that will be readily deformable under the load of the measuring instruments, as the instrument probe must be placed directly on the coating surface to take a reading.
1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM D1400-00 Referenced Document
ASTM D1730 Standard Practices for Preparation of Aluminum and Aluminum-Alloy Surfaces for Painting
ASTM D823 Standard Practices for Producing Films of Uniform Thickness of Paint, Varnish, and Related Products on Test Panels
ASTM D1400-00 history
2000ASTM D1400-00 Standard Test Method for Nondestructive Measurement of Dry Film Thickness of Nonconductive Coatings Applied to a Nonferrous Metal Base
1994ASTM D1400-94 Standard Test Method for Nondestructive Measurement of Dry Film Thickness of Nonconductive Coatings Applied to a Nonferrous Metal Base