ASTM D6113-16
Standard Test Method for Using a Cone Calorimeter to Determine Fire-Test-Response Characteristics of Insulating Materials Contained in Electrical or Optical Fiber Cables

Standard No.
ASTM D6113-16
Release Date
2016
Published By
American Society for Testing and Materials (ASTM)
Status
Replace By
ASTM D6113-21
Latest
ASTM D6113-21
Scope
1.1 This is a fire-test-response standard. 1.2 Several fire-test-response characteristics, including the time to sustained flaming, heat release rate, total heat released, effective heat of combustion, and specific extinction area; are measured or calculated by this test method at a constant radiant heating flux. For specific limitations see also 5.7 and Section 6. 1.3 The tests are conducted by burning the electrical insulating materials contained in electrical or optical fiber cables when the cable test specimens, excluding accessories, are subjected to radiant heat. 1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability or regulatory limitations prior to use. For specific precautionary statements, see Section 7. 1.6 This standard measures and describes the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products or assemblies under actual fire conditions. 1.7 Fire testing is inherently hazardous. Adequate safeguards for personnel and property shall be employed in conducting these tests.

ASTM D6113-16 Referenced Document

  • ANSI/UL 1581 Reference Standard for Safety for Electrical Wires, Cables, and Flexible Cords
  • ANSI/UL 1666 Standard for Safety for Test for Flame Propagation Height of Electrical and Optical-Fiber Cables Installed Vertically in Shafts*2024-04-22 Update
  • ANSI/UL 1685 Standard for Safety for Vertical-Tray Fire-Propagation and Smoke-Release Test for Electrical and Optical-Fiber Cables*2024-04-22 Update
  • ASTM D1711 Standard Terminology Relating to Electrical Insulation
  • ASTM D5424 Standard Test Method for Smoke Obscuration of Insulating Materials Contained in Electrical or Optical Fiber Cables When Burning in a Vertical Cable Tray Configuration
  • ASTM D5485 Standard Test Method for Determining the Corrosive Effect of Combustion Products Using the Cone Corrosimeter
  • ASTM D5537 Standard Test Method for Heat Release, Flame Spread and Mass Loss Testing of Insulating Materials Contained in Electrical or Optical Fiber Cables When Burning in a Vertical Cable Tray Configuration
  • ASTM D618 Standard Practice for Conditioning Plastics for Testing*2021-07-15 Update
  • ASTM E1354 Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter
  • ASTM E1474 Standard Test Method for Determining the Heat Release Rate of Upholstered Furniture and Mattress Components or Composites Using a Bench Scale Oxygen Consumption Calorimeter
  • ASTM E176 Standard Terminology of Fire Standards
  • ASTM E2058 Standard Test Methods for Measurement of Material Flammability Using a Fire Propagation Apparatus (FPA)*2019-07-01 Update
  • ASTM E2965 Standard Test Method for Determination of Low Levels of Heat Release Rate for Materials and Products Using an Oxygen Consumption Calorimeter*2022-11-01 Update
  • ASTM E691 Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method
  • ASTM E906 Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products
  • IEEE 1202 IEEE Standard for Flame-Propagation Testing of Wire and Cable*2023-12-19 Update
  • ISO 11907-4 Plastics - Smoke generation - Determination of the corrosivity of fire effluents - Part 4: Dynamic decomposition method using a conical radiant heater
  • ISO 13943 Fire safety — Vocabulary*2023-09-01 Update

ASTM D6113-16 history

  • 2021 ASTM D6113-21 Standard Test Method for Using Cone Calorimeter to Determine Fire-Test-Response Characteristics of Insulating Materials Contained in Electrical or Optical Fiber Cables
  • 2016 ASTM D6113-16 Standard Test Method for Using a Cone Calorimeter to Determine Fire-Test-Response Characteristics of Insulating Materials Contained in Electrical or Optical Fiber Cables
  • 2011 ASTM D6113-11 Standard Test Method for Using a Cone Calorimeter to Determine Fire-Test-Response Characteristics of Insulating Materials Contained in Electrical or Optical Fiber Cables
  • 2010 ASTM D6113-10 Standard Test Method for Using a Cone Calorimeter to Determine Fire-Test-Response Characteristics of Insulating Materials Contained in Electrical or Optical Fiber Cables
  • 2009 ASTM D6113-09 Standard Test Method for Using a Cone Calorimeter to Determine Fire-Test-Response Characteristics of Insulating Materials Contained in Electrical or Optical Fiber Cables
  • 2003 ASTM D6113-03 Standard Test Method for Using a Cone Calorimeter to Determine Fire-Test-Response Characteristics of Insulating Materials Contained in Electrical or Optical Fiber Cables
  • 2002 ASTM D6113-02 Standard Test Method for Using a Cone Calorimeter to Determine Fire-Test Response Characteristics of Insulating Materials Contained in Electrical or Optical Fiber Cables
  • 1999 ASTM D6113-99 Standard Test Method for Using a Cone Calorimeter to Determine Fire-Test Response Characteristics of Insulating Materials Contained in Electrical or Optical Fiber Cables
Standard Test Method for Using a Cone Calorimeter to Determine Fire-Test-Response Characteristics of Insulating Materials Contained in Electrical or Optical Fiber Cables



Copyright ©2024 All Rights Reserved