1.1 This test method2 covers the determination of mercury in liquid chlorine with a lower limit of detection of
0.1 µg/L.
1.2 Review the current Safety Data Sheet (SDS) for detailed information concerning toxicity, first-aid procedures, and safety precautions.
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Sections 7,
6.3,
6.4,
6.5, and Note 2.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM E506-17a Referenced Document
ASTM D1193 Standard Specification for Reagent Water
ASTM D6809 Standard Guide for Quality Control and Quality Assurance Procedures for Aromatic Hydrocarbons and Related Materials*, 2020-10-01 Update
ASTM E180 Standard Practice for Determining the Precision of ASTM Methods for Analysis and Testing of Industrial and Specialty Chemicals
ASTM E200 Standard Practice for Preparation, Standardization, and Storage of Standard and Reagent Solutions for Chemical Analysis
ASTM E506-17a history
2017ASTM E506-17a Standard Test Method for Mercury in Liquid Chlorine
2017ASTM E506-17 Standard Test Method for Mercury in Liquid Chlorine
2008ASTM E506-08 Standard Test Method for Mercury in Liquid Chlorine
1998ASTM E506-98(2003) Standard Test Method for Mercury in Liquid Chlorine
1998ASTM E506-98 Standard Test Method for Mercury in Liquid Chlorine