IEC 60730-2-5:2009
Dispositifs de commande électrique automatiques à usage domestique et analogue – Partie 2-5: Règles particulières pour les systèmes de commande électrique automatiques des br?leurs (Edition 3.2; Consolidated Reprint)

Standard No.
IEC 60730-2-5:2009
Release Date
2009
Published By
IEC - International Electrotechnical Commission
Status
 2017-09
Replace By
IEC 60730-2-5:2013
Latest
IEC 60730-2-5:2013/COR1:2023
Scope
This clause of part 1 is applicable except as follows: Replacement: This part of IEC 60730 applies to automatic electrical burner control systems for the automatic control of burners for oil@ gas@ coal or other combustibles for household and similar use including heating@ air conditioning and similar use. This part 2-5 is applicable to a complete burner control system and to a separate programming unit. This part 2-5 is also applicable to a separate electronic high-voltage ignition source and to a separate flame detector. Separate ignition devices (electrodes@ pilot burners@ etc.) are not covered by this part 2-5 unless they are submitted as part of a burner control system. Requirements for separate ignition transformers are contained in IEC 60989. Throughout this part 2-5@ where it can be used unambiguously@ the word "system" means "burner control system" and "systems" means "burner control systems".Systems utilizing thermoelectric flame supervision are not covered by this part 2-5.This part 2-5 applies to the inherent safety@ to the manufacturerapos;s declared operating values@ operating times and operating sequences where such are associated with burner safety and to the testing of automatic electrical burner control systems used in@ on@ or in association with@ burners. Requirements for specific operating values@ operating times and operating sequences are given in the standards for appliances and equipment. Systems for equipment not intended for normal household use@ but which nevertheless may be used by the public@ such as equipment intended to be used by laymen in shops@ in light industry and on farms@ are within the scope of this part 2-5. This part 2-5 applies to systems using NTC or PTC thermistors@ additional requirements for which are contained in annex J.This part 2-5 does not apply to systems designed exclusively for industrial applications. This part 2-5 applies to manual controls when such are electrically and/or mechanically integral with automatic controls. Requirements for manual switches not forming part of an automatic control are contained in IEC 61058-1. Throughout this part 2-5@ the word "equipment" means "appliance and equipment".?

IEC 60730-2-5:2009 history

  • 2023 IEC 60730-2-5:2013/COR1:2023 Corrigendum 1 - Automatic electrical controls - Part 2-5: Particular requirements for automatic electrical burner control systems
  • 2021 IEC 60730-2-5:2013/AMD2:2021 Amendment 2 - Automatic electrical controls - Part 2-5: Particular requirements for automatic electrical burner control systems
  • 2021 IEC 60730-2-5:2021 Automatic electrical controls - Part 2-5: Particular requirements for automatic electrical burner control systems
  • 2017 IEC 60730-2-5:2013/AMD1:2017 Amendment 1 - Automatic electrical controls - Part 2-5: Particular requirements for automatic electrical burner control systems
  • 2017 IEC 60730-2-5:2017 Automatic electrical controls – Part 2-5: Particular requirements for automatic electrical burner control systems (Edition 4.1)
  • 2013 IEC 60730-2-5:2013 Automatic electrical controls - Part 2-5: Particular requirements for automatic electrical burner control systems
  • 2009 IEC 60730-2-5:2009 Dispositifs de commande électrique automatiques à usage domestique et analogue – Partie 2-5: Règles particulières pour les systèmes de commande électrique automatiques des br?leurs (Edition 3.2; Consolidated Reprint)
  • 1970 IEC 60730-2-5:2000/AMD2:2008 Amendment 2 - Automatic electrical controls for household and similar use - Part 2-5: Particular requirements for automatic electrical burner control systems
  • 1970 IEC 60730-2-5:2000/AMD1:2004 Amendment 1 - Automatic electrical controls for household and similar use - Part 2-5: Particular requirements for automatic electrical burner control systems
  • 2004 IEC 60730-2-5:2004 Automatic electrical controls for household and similar use - Part 2-5: Particular requirements for automatic electrical burner control systems
  • 2000 IEC 60730-2-5/AMD1:2000 Amendment 1 Automatic electrical controls for household and similar use - Part 2-5: Particular requirements for automatic electrical burner control systems (Edition 3.0; Amendment 1: 07/2004)
  • 2000 IEC 60730-2-5:2000 Automatic electrical controls for household and similar use - Part 2-5: Particular requirements for automatic electrical burner control systems
  • 1970 IEC 60730-2-5:1993/AMD2:1997 Amendment 2 - Automatic electrical controls for household and similar use - Part 2: Particular requirements for automatic electrical burner control systems
  • 1970 IEC 60730-2-5:1993/AMD1:1996 Amendment 1 - Automatic electrical controls for household and similar use - Part 2: Particular requirements for automatic electrical burner control systems
  • 1993 IEC 60730-2-5:1993 Automatic Electrical Controls for Household and Similar Use Part 2: Particular Requirements for Automatic Electrical Burner Control Systems (Edition 2.0; CAN/CSA-IEC E730-2-5-94; Amendment 1-1996; Amendment 2-1997)
  • 1990 IEC 60730-2-5:1990 Automatic electrical controls for household and similar use; part 2: particular requirements for automatic electrical burner control systems