ASTM E3048-16
Standard Test Method for Determination of Time to Burn-Through Using the Intermediate Scale Calorimeter (ICAL) Radiant Panel

Standard No.
ASTM E3048-16
Release Date
2016
Published By
American Society for Testing and Materials (ASTM)
Status
Replace By
ASTM E3048-17
Latest
ASTM E3048-22a
Scope
1.1 This fire-test-response test method assesses the response of materials, products, and assemblies to controlled levels of heat flux with an external igniter. 1.2 The fire-test-response characteristics determined by this test method include the ignitability and time to burn-through of materials, products, and assemblies under well ventilated conditions. 1.3 Heat, smoke, and mass loss rate are not within the scope of this test method, but are addressed by Test Method E1623. 1.3.1 This test method uses the same burner as that described in Test Method E1623. Two burner types are described (Burner A and Burner B). 1.4 Specimens are exposed to a constant heat flux up to 50 kW/m2 in a vertical orientation. Hot wires are used to ignite the combustible vapors from the specimen. 1.5 This test method has been developed for evaluations, design, or research and development of materials, products, or assemblies, or for code compliance. The specimen shall be tested in thicknesses and configurations representative of actual end product or system uses. 1.6 Limitations of the test method are listed in 5.7. 1.7 This test method is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products, or assemblies under actual fire conditions. 1.8 Fire testing is inherently hazardous. Adequate safeguards for personnel and property shall be employed in conducting these tests. 1.9 The values stated in SI units are to be regarded as standard. 1.10 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific information about hazards is given in Section 7.

ASTM E3048-16 Referenced Document

  • ASTM E119 Standard Test Methods for Fire Tests of Building Construction and Materials
  • ASTM E1354 Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter
  • ASTM E1623 Standard Test Method for Determination of Fire and Thermal Parameters of Materials, Products, and Systems Using an Intermediate Scale Calorimeter (ICAL)*2022-11-01 Update
  • ASTM E176 Standard Terminology of Fire Standards
  • ASTM E603 Standard Guide for Room Fire Experiments
  • ASTM E906/E906M Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using a Thermopile Method*2021-12-01 Update

ASTM E3048-16 history

  • 2022 ASTM E3048-22a Standard Test Method for Determination of Time to Burn-Through Using the Intermediate Scale Calorimeter (ICAL) Radiant Panel
  • 2022 ASTM E3048-22 Standard Test Method for Determination of Time to Burn-Through Using the Intermediate Scale Calorimeter (ICAL) Radiant Panel
  • 2019 ASTM E3048-19a Standard Test Method for Determination of Time to Burn-Through Using the Intermediate Scale Calorimeter (ICAL) Radiant Panel
  • 2019 ASTM E3048-19 Standard Test Method for Determination of Time to Burn-Through Using the Intermediate Scale Calorimeter (ICAL) Radiant Panel
  • 2017 ASTM E3048-17 Standard Test Method for Determination of Time to Burn-Through Using the Intermediate Scale Calorimeter (ICAL) Radiant Panel
  • 2016 ASTM E3048-16 Standard Test Method for Determination of Time to Burn-Through Using the Intermediate Scale Calorimeter (ICAL) Radiant Panel
Standard Test Method for Determination of Time to Burn-Through Using the Intermediate Scale Calorimeter (ICAL) Radiant Panel



Copyright ©2024 All Rights Reserved