SAE J2846-2017
Laboratory Measurement of the Acoustical Performance of Body Cavity Filler Materials

Standard No.
SAE J2846-2017
Release Date
2017
Published By
SAE - SAE International
Latest
SAE J2846-2017
Scope
This SAE Recommended Practice describes a laboratory test procedure for measuring the acoustical performance of a system consisting of a body cavity filler material formed into a rectangular cross-section channel. Materials for this test may include both heat reactive and chemically reactive products@ with or without a shelf to simulate a baffle in an application@ or a combination of body cavity filler and aluminum foil to enhance the performance. These materials are commonly installed in transportation systems such as ground vehicles@ and thus reduce the noise propagation through the rails@ rockers@ and pillar/posts. This document is intended to rank order the acoustical performance of materials for application on channels using general automotive steel@ such that the effects of sealing of pinch welds in addition to the material could be easily evaluated. However@ the channel is not an actual part (i.e.@ real life section) of the vehicle@ and therefore results obtained from this study will have to be carefully interpreted considering limitations of section size/shape and full sealing (or not) of the section. The acoustical performance is expressed in terms of insertion loss (IL) which is described in Section 3 Test Method. The test procedure described here is based on the method described in SAE J1400. However@ this document differs from the SAE J1400 method in that the J1400 measures sound transmission loss@ and this document measures IL of body cavity materials in a cavity. This document covers the useful frequency range of interest in 1/3 octave band center frequencies. The lower limit of the actual frequency range is limited by the size of the channel and/or the volume of the reverberation room. Two rectangular cross-section channels are cited in this standard. These are 75 mm x 75 mm and 150 mm x 150 mm in cross-section and provide valid data at and above 800 Hz and 400 Hz 1/3 octave band frequencies@ respectively@ provided the reverberation room can generate diffuse sound field at those frequencies.

SAE J2846-2017 history

  • 2017 SAE J2846-2017 Laboratory Measurement of the Acoustical Performance of Body Cavity Filler Materials
  • 2010 SAE J2846-2010 Laboratory Measurement of the Acoustical Performance of Body Cavity Filler Materials
Laboratory Measurement of the Acoustical Performance of Body Cavity Filler Materials



Copyright ©2024 All Rights Reserved