Scope
1.1 This practice covers procedures to determine the load resistance (LR) of specified glass types, including combinations of glass types used in a sealed insulating glass (IG) unit, exposed to a uniform lateral load of short or long duration, for a specified probability of breakage.

1.2 This practice applies to vertical and sloped glazing in buildings for which the specified design loads consist of wind load, snow load and self-weight with a total combined magnitude less than or equal to 15 kPa (315 psf). This practice shall not apply to other applications including, but not limited to, balustrades, glass floor panels, aquariums, structural glass members, and glass shelves.

1.3 This practice applies only to monolithic and laminated glass constructions of rectangular shape with continuous lateral support along one, two, three, or four edges. This practice assumes that (1) the supported glass edges for two, three, and four-sided support conditions are simply supported and free to slip in plane; (2) glass supported on two sides acts as a simply supported beam; and (3) glass supported on one side acts as a cantilever. For insulating glass units, this practice only applies to insulating glass units with four-sided edge support.

1.4 This practice does not apply to any form of wired, patterned, sandblasted, drilled, notched, or grooved glass. This practice does not apply to glass with surface or edge treatments that reduce the glass strength. NOTE 1—Ceramic enamel is known to affect glass load resistance. Consult the manufacturer for guidance.

1.5 This practice addresses only the determination of the resistance of glass to uniform lateral loads. The final thickness and type of glass selected also depends upon a variety of other factors (see 6.3).

1.6 Charts in this practice provide a means to determine approximate maximum lateral glass deflection. Appendix X1 provides additional procedures to determine maximum lateral deflection for glass simply supported on four sides.

1.7 Appendix X2 lists the key variables used in calculating the mandatory type factors in Tables 1-3 and comments on their conservative values.

1.8 The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard.

1.9 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.10 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

ASTM E1300-24 Referenced Document

  • ASTM C1036 Standard Specification for Flat Glass
  • ASTM C1048 Standard Specification for Heat-Treated Flat Glass--Kind HS, Kind FT Coated and Uncoated Glass
  • ASTM C1172 Standard Specification for Laminated Architectural Flat Glass
  • ASTM D4065 Standard Practice for Plastics: Dynamic Mechanical Properties: Determination and Report of Procedures
  • ASTM E631 Standard Terminology of Building Constructions

ASTM E1300-24 history

  • 2024 ASTM E1300-24 Standard Practice for Determining Load Resistance of Glass in Buildings
  • 2016 ASTM E1300-16 Standard Practice for Determining Load Resistance of Glass in Buildings
  • 2012 ASTM E1300-12ae1 Standard Practice for Determining Load Resistance of Glass in Buildings
  • 2012 ASTM E1300-12a Standard Practice for Determining Load Resistance of Glass in Buildings
  • 2012 ASTM E1300-12 Standard Practice for Determining Load Resistance of Glass in Buildings
  • 2009 ASTM E1300-09a Standard Practice for Determining Load Resistance of Glass in Buildings
  • 2009 ASTM E1300-09 Standard Practice for Determining Load Resistance of Glass in Buildings
  • 2007 ASTM E1300-07e1 Standard Practice for Determining Load Resistance of Glass in Buildings
  • 2004 ASTM E1300-04e1 Standard Practice for Determining Load Resistance of Glass in Buildings
  • 2004 ASTM E1300-04 Standard Practice for Determining Load Resistance of Glass in Buildings
  • 2003 ASTM E1300-03 Standard Practice for Determining Load Resistance of Glass in Buildings
  • 2002 ASTM E1300-02 Standard Practice for Determining Load Resistance of Glass in Buildings
  • 2000 ASTM E1300-00 Standard Practice for Determining Load Resistance of Glass in Buildings
Standard Practice for Determining Load Resistance of Glass in Buildings

Standard and Specification




Copyright ©2024 All Rights Reserved