IEEE C57.12.10-1988
Transformers - 230 kV and Below 833/958 Through 8333/10 417 kVA@ Single-Phase@ and 750/862 Through 60 000/ 80 000/100 000 kVA@ Three-Phase Without Load Tap Changing; and 3750/ 4687 Through 60 000/ 80 000/100 000 kVA with Load Tap Changing - Safety Require

Standard No.
IEEE C57.12.10-1988
Release Date
1988
Published By
IEEE - The Institute of Electrical and Electronics Engineers@ Inc.
Status
 2018-04
Replace By
IEEE C57.12.10-2010
Latest
IEEE C57.12.10-2017
Scope
This standard covers certain electrical@ dimensional@ and mechanical characteristics and takes into consideration certain safety features of 60-Hz@ two-winding@ liquid-immersed transformers rated as follows@ and used for step-down purposes: (1) 833/958 through 8333/10 417 kVA@ single-phase; 750/862 through 10 000/12 500 kVA@ three- phase; high voltage@ 2400 through 138 000 volts; low-voltage@ 480 through 36 230 volts; without load tap changing Note: A subgroup of the above group is also identified as three-phase transformers 750-2500 kVA@ with distribution BIL characteristics. (2) 12 000/16 000/20 000 through 60 000/80 000/100 000 kVA@ three-phase; high voltage@ 23 000 through 230 000 volts; low voltage@ 4800 through 36 230 volts; without load tap changing (3) 3750/4687 through 10 000/12 500 kVA@ three-phase; high voltage@ 6900 through 138 000 volts; low voltage@ 2400 through 36 230 volts; with load tap changing (4) 12 000/16 000/20 000 through 60 000/80 000/100 000 kVA@ three-phase; high voltage@ 23 000 through 230 000 volts; low voltage@ 4800 through 36 230 volts; with load tap changing It is not intended that this standard shall apply to dry-type@ regulating@ pad-mounted@ secondary-network@ furnace@ rectifier@ or mine transformers.?

IEEE C57.12.10-1988 history

  • 2017 IEEE C57.12.10-2017 Requirements for Liquid-Immersed Power Transformers
  • 2010 IEEE C57.12.10-2010 Requirements for Liquid-Immersed Power Transformers
  • 1988 IEEE C57.12.10-1988 Transformers - 230 kV and Below 833/958 Through 8333/10 417 kVA@ Single-Phase@ and 750/862 Through 60 000/ 80 000/100 000 kVA@ Three-Phase Without Load Tap Changing; and 3750/ 4687 Through 60 000/ 80 000/100 000 kVA with Load Tap Changing - Safety Require
  • 1977 IEEE C57.12.10-1977 REQUIREMENTS FOR TRANSFORMERS 230 000 VOLTS AND BELOW 833/958 THROUGH 8333/10 417 KVA@ SINGLE-PHASE@ AND 750/ 862 THROUGH 60 000/ 80 000/100 000 KVA@ THREE-PHASE; ERRATA - APRIL 1978@ SUPPLEMENT C57.12.10A - MAY 1978
  • 1958 IEEE C57.12.10-1958 American Standard Requirements@ Terminology@ and Test Code for Distribution@ Power@ and Regulating Transformers@ and Reactors Other Than Current-Limiting Reactors