ASTM D3161/D3161M-16a
Standard Test Method for Wind-Resistance of Steep Slope Roofing Products (Fan-Induced Method)

Standard No.
ASTM D3161/D3161M-16a
Release Date
2016
Published By
American Society for Testing and Materials (ASTM)
Status
Replace By
ASTM D3161/D3161M-19
Latest
ASTM D3161/D3161M-20
Scope
1.1 This test method covers the procedure for evaluating the wind resistance of many discontinuous, air permeable, steep slope roofing products that results from the product’s rigidity, with or without contribution from sealant to help hold down the leading edge of the tabs, or mechanical interlocking, with or without contribution from sealant to help hold down the leading edge of the tabs, or any combination thereof. The products are applied to a test panel in accordance with the manufacturer’s instructions and tested at a 2:12 (17 %) slope, or at the lowest slope permitted by those instructions. 1.2 This method evaluates wind resistance using a faninduced procedure, delivering a stream of air across the exposed surface of the test specimens. This method does not measure structural performance, and does not provide a measure of uplift resistance. Consequently, this method is not applicable to continuous, non-permeable roof systems or coverings (such as membranes or mechanically-seamed metal roof panels). 1.3 This test method was formerly titled “Wind Resistance of Asphalt Shingles (Fan-Induced Method)” but was revised to acknowledge that the method is applicable to many other steep slope roofing products and has been used to evaluate the wind resistance of those products for many years by several testing and certification laboratories. Steep slope roofing products that fall under the scope of this test method, in addition to asphalt shingles, are polymer-based shingles, fiber-cement shingles, concrete tiles, clay tiles, metal shingles, and photovoltaic shingles. 1.4 This test method is limited to steep slope roofing product applied with a maximum exposure of 410 mm [16 in.]. 1.5 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ASTM D3161/D3161M-16a Referenced Document

  • ASTM D1079 Standard Terminology Relating to Roofing and Waterproofing*2020-05-01 Update

ASTM D3161/D3161M-16a history

  • 2020 ASTM D3161/D3161M-20 Standard Test Method for Wind Resistance of Steep Slope Roofing Products (Fan-Induced Method)
  • 2019 ASTM D3161/D3161M-19a Standard Test Method for Wind Resistance of Steep Slope Roofing Products (Fan-Induced Method)
  • 2019 ASTM D3161/D3161M-19 Standard Test Method for Wind-Resistance of Steep Slope Roofing Products (Fan-Induced Method)
  • 2016 ASTM D3161/D3161M-16a Standard Test Method for Wind-Resistance of Steep Slope Roofing Products (Fan-Induced Method)
  • 2016 ASTM D3161/D3161M-16 Standard Test Method for Wind-Resistance of Steep Slope Roofing Products (Fan-Induced Method)
  • 2015 ASTM D3161/D3161M-15 Standard Test Method for Wind-Resistance of Steep Slope Roofing Products (Fan-Induced Method)
  • 2014 ASTM D3161/D3161M-14 Standard Test Method for Wind-Resistance of Steep Slope Roofing Products 40;Fan-Induced Method41;
  • 2013 ASTM D3161/D3161M-13 Standard Test Method for Wind-Resistance of Steep Slope Roofing Products (Fan-Induced Method)
  • 2012 ASTM D3161/D3161M-12 Standard Test Method for Wind-Resistance of Asphalt Shingles (Fan-Induced Method)
  • 2009 ASTM D3161-09 Standard Test Method for Wind-Resistance of Asphalt Shingles (Fan-Induced Method)
  • 2008 ASTM D3161-08c Standard Test Method for Wind-Resistance of Asphalt Shingles (Fan-Induced Method)
  • 2008 ASTM D3161-08b Standard Test Method for Wind-Resistance of Asphalt Shingles (Fan-Induced Method)
  • 2008 ASTM D3161-08a Standard Test Method for Wind-Resistance of Asphalt Shingles (Fan-Induced Method)
  • 2008 ASTM D3161-08 Standard Test Method for Wind-Resistance of Asphalt Shingles (Fan-Induced Method)
  • 2006 ASTM D3161-06 Standard Test Method for Wind-Resistance of Asphalt Shingles (Fan-Induced Method
  • 2005 ASTM D3161-05 Standard Test Method for Wind-Resistance of Asphalt Shingles (Fan-Induced Method)
  • 2003 ASTM D3161-03b Standard Test Method for Wind-Resistance of Asphalt Shingles (Fan-Induced Method)
  • 2003 ASTM D3161-03a Standard Test Method for Wind-Resistance of Asphalt Shingles (Fan-Induced Method)
  • 2003 ASTM D3161-03 Standard Test Method for Wind-Resistance of Asphalt Shingles (Fan-Induced Method)
  • 1999 ASTM D3161-99a Standard Test Method for Wind-Resistance of Asphalt Shingles (Fan-Induced Method)
Standard Test Method for Wind-Resistance of Steep Slope Roofing Products (Fan-Induced Method)