UL 103 CRD-2013
UL Standard for Safety Factory-Built Chimneys for Residential Type and Building Heating Appliances - Section/Paragraph Reference: Supplement SA Subject: REQUIREMENTS FOR CHIMNEY CONNECTORS FOR SOLID FUEL FIRED ROOM HEATERS AND FIREPLACE STOVES (Edition 11

Standard No.
UL 103 CRD-2013
Release Date
2013
Published By
Underwriters Laboratories (UL)
Status
 2014-02
Replace By
UL 103 BULLETIN-2014
Latest
UL 103-2021
Scope
"These requirements apply to single walled and double walled factory-built chimney connectors. These assemblies do not require field fabrication. They are for use with solid-fuel-fired residential appliances where the flue-gas temperatures do not normally exceed 1000?? Factory-built chimney connectors are intended for use inside buildings to form a connection from an appliance to a factory-built chimney suitable for use with solid fuel. These Factory-built chimney connectors are intended for installation in accordance with the Standard for Chimneys@ Fireplaces@ Vents@ and Solid-Fuel Burning Appliances@ NFPA 211@ and in accordance with codes such as the International Mechanical Code@ the International Residential Code@ and the Uniform Mechanical Code. Factory-built chimney connectors are intended to be installed at the manufacturer's recommended clearance to combustible construction or a minimum clearance of 18 in. (46 cm) to combustible construction and fabricated at the minimum material thickness for steel as required by the Standard for Chimneys@ Fireplaces@ Vents@ and Solid-Fuel Burning Appliances@ NFPA 211 and as described herein. These requirements supplement those specified in the Standard for Factory-Built Chimneys for Residential Type and Building Heating Appliances@ UL 103@ and are not to supersede the requirements of UL 103. (i.e. UL 103 takes precedence over this Supplement) with the following exceptions: a) The table shown in SA3.1.2 applies to chimney connectors@ in lieu of the requirements in Table 6.1 ""Minimum thickness of chimney material"" of UL 103. b) The Markings and Instructions requirements shown in SA5 and SA6@ respectively@ apply to chimney connectors in lieu of the Markings and Instructions requirements of UL 103."

UL 103 CRD-2013 history

  • 1970 UL 103-2021 Chimneys, factory-built, residential type and building heating appliance
  • 2016 UL 103 BULLETIN-2016 UL Standard for Safety Factory-Built Chimneys for Residential Type and Building Heating Appliances (COMMENTS DUE: JANUARY 23@ 2017)
  • 2015 UL 103 BULLETIN-2015 UL Standard for Safety Factory-Built Chimneys for Residential Type and Building Heating Appliances (COMMENTS DUE: May@ 25@ 2015)
  • 2014 UL 103 BULLETIN-2014 UL Standard for Safety Factory-Built Chimneys for Residential Type and Building Heating Appliances (COMMENTS DUE: MARCH 26@ 2014)
  • 2013 UL 103 CRD-2013 UL Standard for Safety Factory-Built Chimneys for Residential Type and Building Heating Appliances - Section/Paragraph Reference: Supplement SA Subject: REQUIREMENTS FOR CHIMNEY CONNECTORS FOR SOLID FUEL FIRED ROOM HEATERS AND FIREPLACE STOVES (Edition 11
  • 2013 UL 103 BULLETIN-2013 UL Standard for Safety Factory-Built Chimneys for Residential Type and Building Heating Appliances (COMMENTS DUE: August 09@ 2013)
  • 2012 UL 103 BULLETIN-2012 UL Standard for Safety Factory-Built Chimneys for Residential Type and Building Heating Appliances (COMMENTS DUE: MAY 21@ 2012)
  • 2011 UL 103 BULLETIN-2011 UL Standard for Safety Factory-Built Chimneys for Residential Type and Building Heating Appliances (COMMENTS DUE: DECEMBER 28@ 2011)
  • 2010 UL 103 BULLETIN-2010 UL Standard for Safety Factory-Built Chimneys for Residential Type and Building Heating Appliances (COMMENTS DUE: MAY 28@ 2010)
  • 2010 UL 103-2010 UL Standard for Safety Factory-Built Chimneys for Residential Type and Building Heating Appliances (Eleventh Edition; Reprint with revisions through and including July 27@ 2012)
  • 2009 UL 103 BULLETIN-2009 UL Standard for Safety Factory-Built Chimneys for Residential Type and Building Heating Appliances (COMMENTS DUE: May 06@ 2009)
  • 2007 UL 103 BULLETIN-2007 UL Standard for Safety Factory-Built Chimneys for Residential Type and Building Heating Appliances
  • 2006 UL 103 BULLETINS-2006 CSDS 1/20/2006 (6p)
  • 2006 UL 103 BULLETIN-2006 UL Standard for Safety Factory-Built Chimneys for Residential Type and Building Heating Appliances
  • 2005 UL 103 BULLETINS-2005 CSDS 10/26/05 (8p); CSDS 06/17/05 (58p)
  • 2001 UL 103-2001 UL Standard for Safety Factory-Built Chimneys for Residential Type and Building Heating Appliances (Tenth Edition; Reprint with Revisions Through and Including June 30@ 2006)
  • 2000 UL 103 BULLETIN-2000 UL Standard for Safety Factory-Built Chimneys for Residential Type and Building Heating Appliances
  • 1995 UL 103-1995 UL Standard for Safety Factory-Built Chimneys for Residential Type and Building Heating Appliances (Ninth Edition; Reprint with Revisions Through and Including March 17@ 1999)
  • 1994 UL 103-1994 Chimneys, factory-built, residential type and building heating appliance



Copyright ©2024 All Rights Reserved