UL 48 BULLETIN-2007
UL Standard for Safety for Electric Signs

Standard No.
UL 48 BULLETIN-2007
Release Date
2007
Published By
Underwriters Laboratories (UL)
Status
 2011-09
Replace By
UL 48 BULLETIN-2008
Latest
UL 48-2022
Scope
These requirements cover electric signs@ referred to as signs@ using incandescent lamps@ fluorescent lamps@ HID lamps@ neon tubing and other combinations@ for use in accordance with the National Electrical Code@ NFPA 70.The signs covered by these requirements include@ and are not limited to@ awning signs@ channel-letter signs@ directional signs@ ordinary box signs@ recessed signs@ trailer-mounted signs@ and other similar signs.These requirements do not cover units specifically intended for billboard illumination@ "EXIT" lights@ show-window signs using skeleton neon tubing with exposed wiring@ or illuminated clocks in which a potential of 600 volts or less is involved.These requirements do not cover signs not provided with electrical means for illumination.These requirements do not cover signs specifically intended for connection to a circuit of limited power supplied by a Class 2 transformer with 30 volts or less output. These requirements cover signs that incorporate a Class 2 transformer as an integral part of the sign.These requirements do not cover the trailer of a trailer-mounted sign.These requirements do not cover field-assembled signs for outline lighting. These requirements cover outline lighting that is factory assembled and that is capable of being sectionalized for shipping purposes.The following types of signs that do not include words or symbols are also covered by these requirements:a) An incandescent-lamp sign provided with a flasher@ or means for remote installation of a flasher;b) A sign without a face and having a trough@ track@ or similar parts for field installation of a rigid or a flexible face and advertising material. See 40.1.13;c) An illuminated module of a sign used as a spacer between modules containing words or symbols;d) An outdoor sign intended for use as outline lighting. See 40.4.1; ande) A sign having a blank face that is intended to have advertising material applied prior to the installation of the sign. See 40.1.12.These requirements do not cover electronic controls covered by the Standard for Control Centers for Changing Message Type Electric Signs@ UL 1433. However@ this does not preclude the use of these types of controls in signs when they are used in accordance with 2.1.1.

UL 48 BULLETIN-2007 history

  • 1970 UL 48-2022 UL Standard for Safety for Electric Signs
  • 2018 UL 48 BULLETIN-2018 UL Standard for Safety Electric Signs (COMMENTS DUE: AUGUST 13@ 2018)
  • 2017 UL 48 BULLETIN-2017 UL Standard for Safety Electric Signs (COMMENTS DUE: October 23@ 2017)
  • 2015 UL 48 CRD-2015 UL Standard for Safety Electric Signs - Section / Paragraph Reference: 2.65.1@ 4.4.6.1.1@ 4.4.6.1.6@ 7.7.2@ and 8.2.2 Subject: Rough-In Sign Sections (Edition 15: September 02@ 2011)
  • 2014 UL 48 BULLETIN-2014 UL Standard for Safety Electric Signs (COMMENTS DUE: SEPTEMBER 8@ 2014)
  • 2013 UL 48 CRD-2013 UL Standard for Safety Electric Signs - Section / Paragraph Reference: (New) 4.4.12 Subject: Photovoltaic Electric Signs (Edition 15: September 02@ 2011)
  • 2012 UL 48 CRD-2012 UL Standard for Safety Electric Signs - Section / Paragraph Reference: Par 4.1.3.2.3.9 Subject: Use of Screens or Mesh Over Drain Openings in Signs (Edition 15: September 02@ 2011)
  • 2012 UL 48 BULLETIN-2012 UL Standard for Safety Electric Signs (COMMENTS DUE: JANUARY 23@ 2013)
  • 2011 UL 48 BULLETIN-2011
  • 2011 UL 48-2011 UL Standard for Safety Electric Signs (Fifteenth Edition; Reprint with Revisions Through and Including November 10@ 2017)
  • 2010 UL 48 BULLETIN-2010 UL Standard for Safety Electric Signs (COMMENTS DUE: MARCH 26@ 2010)
  • 2009 UL 48 BULLETIN-2009 UL Standard for Safety for Electric Signs
  • 2008 UL 48 BULLETIN-2008 UL Standard for Safety for Electric Signs
  • 2007 UL 48 BULLETIN-2007 UL Standard for Safety for Electric Signs
  • 2006 UL 48 BULLETINS-2006 CSDS 03/24/2006 (98p)
  • 2006 UL 48 BULLETIN-2006 UL Standard for Safety for Electric Signs
  • 2005 UL 48 BULLETINS-2005 UL Standard for Safety for Electric Signs (11/11/2005 (98p); 03/18/2005 (18p))
  • 2004 UL 48 BULLETINS-2004 UL Standard for Safety for Electric Signs (09/17/2004 (204p); 08/04/2004 (8p); 07/02/2004 (10p))
  • 2003 UL 48 BULLETINS-2003 UL Standard for Safety for Electric Signs (08/12/2003 (16p); 06/23/2003 (12p))
  • 2002 UL 48 BULLETINS-2002 UL Standard for Safety for Electric Signs (11/08/2002 (4p); 06/27/2002 (4p))
  • 2001 UL 48 BULLETINS-2001 3/20/2001 (2p)
  • 2001 UL 48 BULLETIN-2001 UL Standard for Safety for Electric Signs
  • 2000 UL 48 BULLETINS-2000 UL Standard for Safety for Electric Signs (05/22/2000 (3p); 02/04/2000 (37p))
  • 1996 UL 48-1996 UL Standard for Safety for Electric Signs Fourteenth Edition; Reprint with Revisions Through and Including 10/15/2004
  • 1988 UL 48-1988 Electric signs



Copyright ©2024 All Rights Reserved