ASTM D5902-05(2019)
Standard Test Method for Rubber—Determination of Residual Unsaturation in Hydrogenated Nitrile Rubber (HNBR) by Iodine Value

Standard No.
ASTM D5902-05(2019)
Release Date
2019
Published By
American Society for Testing and Materials (ASTM)
Status
Replace By
ASTM D5902-05(2023)
Latest
ASTM D5902-05(2023)
Scope
1.1 This test method covers the Wiijs procedure for the determination of unsaturation (iodine value) in hydrogenated nitrile rubbers. 1.2 This test method is applicable only to those hydrogenated nitrile rubbers derived from copolymers of acrylonitrile and butadiene. 1.3 Iodine values are reported in centigrams of iodine per gram of HNBR [cg(I2)/g]. Higher iodine values indicate higher levels of unsaturation. 1.4 This test method is appropriate for calculating the percent residual unsaturation of hydrogenated nitrile rubber if the iodine value of the base polymer before hydrogenation has been determined. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

ASTM D5902-05(2019) Referenced Document

  • ASTM D1193 Standard Specification for Reagent Water
  • ASTM D1959 
  • ASTM D4483 Standard Practice for Determining Precision for Test Method Standards in the Rubber and Carbon Black Industries

ASTM D5902-05(2019) history

  • 2023 ASTM D5902-05(2023) Standard Test Method for Rubber—Determination of Residual Unsaturation in Hydrogenated Nitrile Rubber (HNBR) by Iodine Value
  • 2019 ASTM D5902-05(2019) Standard Test Method for Rubber—Determination of Residual Unsaturation in Hydrogenated Nitrile Rubber (HNBR) by Iodine Value
  • 2005 ASTM D5902-05(2015) Standard Test Method for Rubber&x2014;Determination of Residual Unsaturation in Hydrogenated Nitrile Rubber (HNBR) by Iodine Value
  • 2005 ASTM D5902-05(2010) Standard Test Method for Rubber-Determination of Residual Unsaturation in Hydrogenated Nitrile Rubber (HNBR) by Iodine Value
  • 2005 ASTM D5902-05e1 Standard Test Method for Rubber-Determination of Residual Unsaturation in Hydrogenated Nitrile Rubber (HNBR) by Iodine Value
  • 2005 ASTM D5902-05 Standard Test Method for Rubber-Determination of Residual Unsaturation in Hydrogenated Nitrile Rubber (HNBR) by Iodine Value
  • 1996 ASTM D5902-96(2001) Standard Test Method for Rubber-Determination of Residual Unsaturation in Hydrogenated Nitrile Rubber (HNBR) by Iodine Value
  • 1996 ASTM D5902-96 Standard Test Method for Rubber-Determination of Residual Unsaturation in Hydrogenated Nitrile Rubber (HNBR) by Iodine Value
Standard Test Method for Rubber—Determination of Residual Unsaturation in Hydrogenated Nitrile Rubber (HNBR) by Iodine Value



Copyright ©2024 All Rights Reserved