ASHRAE 90.4 ADD B-2018
Energy Standard for Data Centers

Standard No.
ASHRAE 90.4 ADD B-2018
Release Date
2018
Published By
ASHRAE - American Society of Heating@ Refrigerating and Air-Conditioning Engineers@ Inc.
Status
Replace By
ASHRAE 90.4 ADD B-2020
Latest
ASHRAE 90.4 ADD B-2020
Scope
FOREWORD Addendum b cleans up redundant wording in Section 4.1.1.2 and creates a more level planning field in Section 4.2.1.2 while eliminating inappropriate text. The addendum clarifies the exception in Section 6.1.1.2 that addresses the case where existing HVAC systems and equipment serve an addition@ and it adds parallel criteria to Section 8.1.3 for electrical equipment. The exception to Section 4.2.1.2 is deleted. The exception addresses increases in floor area and increases in connected load. In terms of the first aspect@ providing an exemption for an increase in area is inequitable: there is no exemption for 10% of the floor area in a new building@ and some additions to existing buildings can be as large as a stand-alone new building. All new floor area should be treated the same. Further@ codes in general require compliance for new construction@ and this change would better align Standard 90.4 with codes. In terms of the second aspect@ this is the wrong location to address most increases in connected load. A build-out or expansion of ITE within the shell of an existing building envelope is considered an alteration@ not an addition. Consequently@ increases in connected load are most appropriately addressed in the alterations section. In Section 6@ the base requirements for additions to existing data centers remain unchanged. The exception to Section 6.1.1.2 is revised to clarify the distinctions between the use of existing HVAC systems and equipment to serve a new addition versus the installation of new HVAC systems and equipment. The language parallels the requirements in Standard 90.1@ Section 6. Section 8 in Standard 90.4 did not specifically address additions to existing data centers. The proposed base requirements match the requirements in Standard 90.1@ Section 8. The new exception to Section 8.1.3 is written to parallel the exception in Section 6 above. (Standard 90.1@ Section 8@ does not contain such an exception.) This addendum only addresses additions to existing data centers. The issue of alterations to existing data centers is addressed in Addendum a. Note: In this addendum@ changes to the current standard are indicated in the text by underlining (for additions) and strikethrough (for deletions) unless the instructions specifically mention some other means of indicating the changes.

ASHRAE 90.4 ADD B-2018 history




Copyright ©2024 All Rights Reserved