UL 486C BULLETIN-2017
UL Standard for Safety Splicing Wire Connectors (COMMENTS DUE: October 10@ 2017)

Standard No.
UL 486C BULLETIN-2017
Release Date
2017
Published By
Underwriters Laboratories (UL)
Status
 2018-01
Replace By
UL 486C-2018
Latest
UL 486C-2021
Scope
This Standard applies to single-polarity@ hand- or tool-applied splicing wire and cable connectors intended for use with all alloys of copper@ aluminum conductors@ or copper-clad aluminum conductors@ or all three@ in accordance with the Canadian Electrical Code Part I@ C22.1@ in Canada@ the National Electrical Code@ NFPA-70@ in the United States of America@ or the Standard for Electrical Installations@ NOM-001-SEDE@ in Mexico@ as follows: Note: Copper-clad aluminum conductors are for use only in the United States in accordance with the National Electrical Code@ NFPA 70. a) connectors intended to hold two or more conductor(s); b) connectors intended for use in appliances and equipment that comply with the requirements for such appliances and equipment; c) connectors intended for use with 6 AWG (13.3 mm2) or smaller conductors; and d) uninsulated connectors that are used in circuits rated 8 000 V and less. ; and e) connectors intended for use in air-handling spaces. Note: Examples of splicing wire connectors include twist-on connectors@ insulation-piercing or displacement connectors@ spring-action connectors@ tool-applied crimp@ mechanical set-screw connectors@ etc. This Standard is intended for splicing wire connectors suitable for use with conductors in the size ranges as follows: a) Aluminum: 1) 12 AWG (3.3 mm2) and 10 AWG (5.3 mm2) solid; 2) 12 AWG (3.3 mm2) to 6 AWG (13.3 mm2) stranded@ Class B concentric@ compressed@ and compact; and 3) 12 AWG (3.3 mm2) to 6 AWG (13.3 mm2) stranded single input wire (SIW). In Mexico@ the use of aluminum conductors is permitted only with thermoset insulation and for sizes of 6 AWG (13.3 mm2) and higher. b) Copper-clad aluminum: 1) In Canada@ this construction is not allowed. 2) In Mexico@ this construction is not allowed. 3) In the United States: i) 12 AWG (3.3 mm2) and 10 AWG (5.3 mm2) solid; and ii) 12 AWG (3.3 mm2) to 6 AWG (13.3 mm2) stranded@ Class B concentric@ compressed@ and Class C concentric. c) Copper: 1) 30 AWG (0.05 mm2) to 10 AWG (5.3 mm2) solid; and 2) 30 AWG (0.05 mm2) to 6 AWG (13.3 mm2) stranded@ Class B concentric and compressed@ and Class C concentric. d) Compact-stranded copper conductors: In Canada and Mexico@ for 8 AWG (8.4 mm2) and 6 AWG (13.3 mm2). In the United States this is not applicable. e) Rigid (solid and stranded) metric wire falling within the ranges of the above AWG sizes. Note: For example@ a connector rated for 6 AWG (13.3 mm2) ?C 14 AWG (2.1 mm2) may be additionally rated for 10 ?C 2.5 mm2. f) Other class and strand configurations as indicated by marking. These requirements cover splicing wire connectors intended for: a) copper-to-copper; b) aluminum-to-aluminum; c) copper-clad aluminum-to-copper-clad aluminum; d) copper-to-aluminum or copper-clad aluminum and aluminum-to-copper-clad aluminum conductor combinations intended for intermixing of conductors and dry locations only; or e) all of the above. This Standard is intended for splicing wire connectors suitable for currents not exceeding the ampacity of insulated conductors rated 75 ??or 90 ?? in accordance with the rating of the connector. For products intended for use in Canada@ general requirements are given in CAN/CSA-C22.2 No. 0. This Standard does not apply to: a) insulated splicing wire connectors intended for use at voltage levels in excess of 2 000 b) terminal wire connectors; c) wire binding screw terminals; d) built-in terminal connectors on devices rated less than 30 A and intended for outlet box mounting or having provision for stress relief; e) built-in terminal connectors on devices having integral cable clamps; f) flat quick connect terminals; and g) soldering lugs.

UL 486C BULLETIN-2017 history

  • 1970 UL 486C-2021 Splicing wire connectors
  • 2019 UL 486C BULLETIN-2019 UL Standard for Safety Splicing Wire Connectors (COMMENTS DUE: July 29@ 2019)
  • 2018 UL 486C BULLETIN-2018 UL Standard for Safety Splicing Wire Connectors (COMMENTS DUE: October 19@ 2018)
  • 2018 UL 486C-2018 UL Standard for Safety Splicing Wire Connectors (Seventh Edition)
  • 2017 UL 486C BULLETIN-2017 UL Standard for Safety Splicing Wire Connectors (COMMENTS DUE: October 10@ 2017)
  • 2016 UL 486C CRD-2016 UL Standard for Safety Splicing Wire Connectors - Section / Paragraph Reference: 1.5@ 10.4@ 10.5@ Table 2@ Table 22 Subject: Increase Voltage Ratings to 2000 Volts (Edition 6: January 11@ 2013)
  • 2015 UL 486C BULLETIN-2015 UL Standard for Safety Splicing Wire Connectors (COMMENTS DUE: OCTOBER 16@ 2015)
  • 2014 UL 486C CRD-2014 UL Standard for Safety Splicing Wire Connectors - Section / Paragraph Reference: 1.1@ 2.1.3@ 2.1.4@ 2.1.5@ 2.1.6@ 6.3.10@ 7.15@ 8.15@ 9.15@ 10.25@ Table 8@ Annex F Subject: Addition of Plenum Requirements for Wire Connectors (Edition 6: January 11@ 2013)
  • 2013 UL 486C BULLETIN-2013 UL Standard for Safety Splicing Wire Connectors (COMMENTS DUE: JUNE 10@ 2013)
  • 2013 UL 486C-2013 UL Standard for Safety Splicing Wire Connectors (Sixth Edition)
  • 2012 UL 486C BULLETIN-2012 UL Standard for Safety Splicing Wire Connectors (COMMENTS DUE: OCTOBER 23@ 2012)
  • 2009 UL 486C BULLETIN-2009 UL Standard for Safety Splicing Wire Connectors (COMMENTS DUE: September 07@ 2009)
  • 2008 UL 486C BULLETIN-2008 UL Standard for Safety Splicing Wire Connectors (COMMENTS DUE: February 02@ 2008)
  • 2006 UL 486C BULLETINS-2006 CSDS 03/17/2006 (10p); CSDS 01/27/2006 (10p)
  • 2004 UL 486C BULLETINS-2004 4/29/2004 (12p)
  • 2004 UL 486C BULLETIN-2004 UL Standard for Safety Splicing Wire Connectors
  • 2004 UL 486C-2004 Splicing wire connectors
  • 2003 UL 486C BULLETINS-2003 (DRAFT) UL Standard for Safety Splicing Wire Connectors Proposed Fifth Edition; Comments Due by March 2, 2004
  • 2003 UL 486C BULLETIN-2003 UL Standard for Safety Splicing Wire Connectors
  • 2000 UL 486C BULLETINS-2000 UL Standard for Safety Splicing Wire Connectors (07/31/2001 (2p); 12/18/2000 (14p))
  • 2000 UL 486C-2000 Splicing wire connectors
  • 1997 UL 486C-1997 Splicing wire connectors
  • 1991 UL 486C-1991 Splicing wire connectors



Copyright ©2024 All Rights Reserved