HJ 972-2018
Monitoring method for electromagnetic radiation environment (English Version)

Standard No.
HJ 972-2018
Language
Chinese, Available in English version
Release Date
2019
Published By
Professional Standard - Environmental Protection
Latest
HJ 972-2018
Scope
This standard specifies the content, methods and other technical requirements for electromagnetic radiation environmental monitoring of mobile communication base stations. This standard applies to electromagnetic radiation environment monitoring of mobile communication base stations outside the exemption scope specified in GB8702. The electromagnetic radiation environment monitoring of mobile communication base stations that are exempt from management may be implemented with reference to this standard. 2 Isotropic standard 2 Minimum field strength ≤7×10-6 W/m2 (0.05 V/m) Maximum field strength ≥25 W/m2 (100 V/m) Isotropic within its measurement range, each of the probe The monitoring condition of homotropy ≤ 2.5 dB is monitored during the normal working hours of the mobile communication base station. 2 Antenna height above the ground Antenna bracket type Number of antennas Operating status Monitoring condition information Monitoring time Year, month and day: ~ Weather conditions: Measuring instrument model Measuring instrument number Ambient temperature ~ ℃ Probe (antenna) model Relative humidity ~ % Probe (antenna) number Base station Schematic diagram of environmental monitoring points on page 6 HJ972—2018 Table A.1 On-site monitoring record table (2) Common base station name Page Monitoring location Monitoring result serial number Monitoring point name Monitoring value (unit: distance from the antenna (m ) vertical horizontal 1 2

HJ 972-2018 history

  • 2019 HJ 972-2018 Monitoring method for electromagnetic radiation environment
Monitoring method for electromagnetic radiation environment



Copyright ©2024 All Rights Reserved