R 32-2009
Standard Practice for Calibrating the Load Cell and Deflection Sensors for a Falling Weight Deflectometer

Standard No.
R 32-2009
Release Date
2009
Published By
AASHTO - American Association of State Highway and Transportation Officials
Status
 2015-08
Replace By
R 32-2011
Latest
R 32-2019
Scope
This standard practice covers the annual calibration of the load cell and the deflection sensors and the monthly relative calibration of the deflection sensors of a falling weight deflectometer (FWD). It is used to establish calibration factors for correcting FWD measurements. This procedure is not applicable to the calibration of cyclic loading and other types of pavement deflection testing equipment. Annual calibration is performed at least once per year or as soon as possible after a deflection sensor or a load cell has been replaced on the FWD. It shall be performed by a certified technician. Monthly relative calibration is performed on the deflection sensors at least once per month and immediately after a deflection sensor is replaced. A certified technician is not required. The procedure results in calibration factors are entered into the FWD software as multipliers. When the FWD measurements are multiplied by the calibration factors the result is a set of measurements that have been corrected to agree with the calibration instrumentation. Calibration procedures may vary slightly among FWD types. This procedure can be used for all types of FWDs with minor modifications within the limits of the reference calibration equipment. This procedure has been automated in the software package WinFWDCal. It is required that the computer program be used to carry out the procedure. To use this procedure@ the FWD computer must be capable of electronic data transfer. Data files for all types of FWDs can be read by the WinFWDCal software. The PDDX file format is required for data input. FWD data files that are in native format can be converted to PDDX format using PDDXconvert@ which is both an integral component in WinFWDCal and a standalone utility. The values stated in SI units are to be regarded as standard. Imperial units given in parentheses are for information purposes only. This standard practice may involve hazardous materials@ operations@ and equipment. It does not purport to address all of the safety concerns associated with its use. It is the responsibility of the user of this standard practice to consult and establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

R 32-2009 history

  • 2019 R 32-2019 Standard Practice for Calibrating the Load Cell and Deflection Sensors for a Falling Weight Deflectometer
  • 2011 R 32-2011 Standard Practice for Calibrating the Load Cell and Deflection Sensors for a Falling Weight Deflectometer
  • 2009 R 32-2009 Standard Practice for Calibrating the Load Cell and Deflection Sensors for a Falling Weight Deflectometer
  • 2003 R 32-2003 Standard Recommended Practice for Calibrating the Load Cell and Deflection Sensors for a Falling Weight Deflectometer