ASTM D7338-14(2023)
Standard Guide for Assessment Of Fungal Growth in Buildings

Standard No.
ASTM D7338-14(2023)
Release Date
2023
Published By
American Society for Testing and Materials (ASTM)
Latest
ASTM D7338-14(2023)
Scope
1.1 This guide provides a compendium of information and a menu of options for assessment of fungal growth in buildings, but does not recommend a specific course of action. Due to the wide variety of fungal problems affecting buildings and their occupants, and the wide variety of buildings, it is not possible to describe a set of uniform steps that will always be performed during an assessment (that is, a standard practice); therefore the user of this guide must decide which steps are appropriate for a given situation or building. 1.2 This guide is specific to fungal growth, which is only one potential problem in a building environment. It may be part of, but is not intended to take the place of, a comprehensive indoor air quality investigation. 1.3 This guide describes minimum steps and procedures for collecting background information on a building in question, procedures for evaluating the potential for moisture infiltration or collection, procedures for inspection for suspect fungal growth, and procedures beyond the scope of a basic survey that may be useful for specific problems. 1.4 Assessments for fungal growth may be useful wherever fungal growth is suspected, excess moisture has been present or when there are concerns regarding potential fungal growth. 1.5 Periodic fungal assessment in buildings may be a component of preventative maintenance programs. 1.6 This guide is applicable to buildings including residential (for example, single or multi-family), institutional (for example, schools, hospitals), government, public assembly, commercial (for example, office, retail), and industrial facilities. 1.7 Recommendations for developing a sampling strategy or methods for the collection and analysis of fungal samples are beyond the scope of this guide. For recommendations for developing a sampling strategy, see Ref (1)2 , Chapter 10. 1.8 Recommendations for remediation of fungal growth are beyond the scope of this guide. 1.9 This guide is not intended to supersede any government regulations governing the assessment of fungal growth in buildings. 1.10 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.11 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

ASTM D7338-14(2023) Referenced Document

  • ASTM C1699 Standard Test Method for Moisture Retention Curves of Porous Building Materials Using Pressure Plates*2023-03-15 Update
  • ASTM C755 Standard Practice for Selection of Vapor Retarders for Thermal Insulation
  • ASTM D4442 Standard Test Methods for Direct Moisture Content Measurement of Wood and Wood-Base Materials
  • ASTM D653 Standard Terminology Relating to Soil, Rock, and Contained Fluids
  • ASTM E1105 Standard Test Method for Field Determination of Water Penetration of Installed Exterior Windows, Skylights, Doors, and Curtain Walls, by Uniform or Cyclic Static Air Pressure Difference*2023-02-01 Update
  • ASTM E1186 Standard Practices for Air Leakage Site Detection in Building Envelopes and Air Retarder Systems
  • ASTM E1356 Standard Test Method for Assignment of the Glass Transition Temperatures by Differential Scanning Calorimetry or Differential Thermal Analysis
  • ASTM E2128 Standard Guide for Evaluating Water Leakage of Building Walls
  • ASTM E2270 Standard Practice for Periodic Inspection of Building Facades for Unsafe Conditions
  • ASTM E331 Standard Test Method for Water Penetration Of Exterior Windows, Curtain Walls, And Doors By Uniform Static Air Pressure Difference
  • ASTM E547 Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Cyclic Static Air Pressure Difference*2024-04-21 Update
  • ASTM E631 Standard Terminology of Building Constructions

ASTM D7338-14(2023) history

  • 2023 ASTM D7338-14(2023) Standard Guide for Assessment Of Fungal Growth in Buildings
  • 2014 ASTM D7338-14 Standard Guide for Assessment Of Fungal Growth in Buildings
  • 2010 ASTM D7338-10 Standard Guide for Assessment Of Fungal Growth in Buildings
Standard Guide for Assessment Of Fungal Growth in Buildings



Copyright ©2024 All Rights Reserved