UL 2196-2017
UL Standard for Safety Fire Test for Circuit Integrity of Fire-Resistive Power@ Instrumentation@ Control and Data Cables (Second Edition; Reprint with revisions through and including November 30@ 2018)

Standard No.
UL 2196-2017
Release Date
2017
Published By
Underwriters Laboratories (UL)
Status
 2018-02
Replace By
UL 2196 BULLETIN-2017
Latest
UL 2196 BULLETIN-2023
Scope
The intent of this Standard is to evaluate the integrity of power@ control@ instrumentation@ and data cables for their ability to maintain circuit integrity when subjected to standard fire test exposure and associated hose stream test. The power@ control@ instrumentation@ and data cables covered by this Standard are intended to comply with the following requirements : In Canada: Canadian Electrical Code and the National Building Code of Canada; In the United States: National Electrical Code@ and/or the National Fire Alarm and Signaling Code@ and/or the Standard for Fixed Guideway Transit and Passenger Rail Systems@ and/or the Standard for Road Tunnels@ Bridges@ and Other Limited Access Highways. Power@ control@ and instrumentation cables are subjected to the fire exposure in accordance with CAN/ULC-S101@ Standard Methods of Fire Endurance Tests of Building Construction and Materials@ and ANSI/UL 263@ Standard for Fire Tests of Building Construction and Materials. During the fire test@ cables are continuously energized at their maximum rated voltage or maximum utilization voltage (power cables); or at their maximum utilization voltage (control and instrumentation cables) and evaluated for circuit integrity. Insulation resistance measurements are also taken to quantify leakage current. Following the fire test@ the assembly shall be subjected to a hose stream test. Data cables are subjected to the fire exposure in accordance with CAN/ULC-S101@ Standard Methods of Fire Endurance Tests of Building Construction and Materials@ and ANSI/UL 263@ Standard for Fire Tests of Building Construction and Materials. During the fire tests@ the data cables are evaluated for their ability to maintain error free data transfer and retrieval at the specified protocol and data rates. Following the fire test@ the assembly shall be subjected to a hose stream test. The fire exposure and hose stream tests are not intended to be representative of all fire conditions and impact conditions@ respectively. It is likely that conditions will vary with changes in the amount@ nature@ distribution of fire loading@ ventilation@ compartment size and configuration@ and heat conducting and dissipating characteristics of the compartment in which the cables are installed. These requirements provide a relative measure of fire performance of comparable assemblies under these specified fire exposure conditions. It is possible that any variation from the construction or operating condition tested@ such as size@ method of assembly and materials@ will substantially change the performance characteristics of the cables. The standardized fire and hose stream exposures for comparing the performance of cables represents one factor in determining the acceptability of cables for use in specific applications. The construction and operation of the furnace and the general test conditions are intended to be in accordance with the requirements in CAN/ULC S101@ Standard Methods of Fire Endurance Tests of Building Construction and Materials@ and ANSI/UL 263@ Standard for Fire Tests of Building Construction and Materials.

UL 2196-2017 history

  • 2023 UL 2196 BULLETIN-2023 UL Standard for Safety Fire Test for Circuit Integrity of Fire-Resistive Power, Instrumentation, Control and Data Cables
  • 1970 UL 2196-2020 UL Standard for Safety Tests for Fire Resistive Cables
  • 2018 UL 2196 BULLETIN-2018 UL Standard for Safety Fire Test for Circuit Integrity of Fire-Resistive Power@ Instrumentation@ Control@ and Data Cables (COMMENTS DUE: April 24@ 2018)
  • 2017 UL 2196 BULLETIN-2017 UL Standard for Safety Tests for Fire Resistive Cables (COMMENTS DUE: MAY 29@ 2017)
  • 2017 UL 2196-2017 UL Standard for Safety Fire Test for Circuit Integrity of Fire-Resistive Power@ Instrumentation@ Control and Data Cables (Second Edition; Reprint with revisions through and including November 30@ 2018)
  • 2016 UL 2196 BULLETIN-2016 UL Standard for Safety Tests for Fire Resistive Cables (COMMENTS DUE: November 22@ 2016)
  • 2014 UL 2196 BULLETIN-2014 UL Standard for Safety Tests for Fire Resistive Cables
  • 2011 UL 2196 BULLETIN-2011 UL Standard for Safety Tests for Fire Resistive Cables (COMMENTS DUE: June 20@ 2012)
  • 2006 UL 2196 BULLETIN-2006 UL Standard for Safety Tests for Fire Resistive Cables
  • 2005 UL 2196 BULLETIN-2005 UL Standard for Safety Tests for Fire Resistive Cables
  • 2001 UL 2196-2001 UL Standard for Safety Tests for Fire Resistive Cables



Copyright ©2024 All Rights Reserved