SAE J1861-2016
Air Brake Valve Input-Output Characteristic Requirements

Standard No.
SAE J1861-2016
Release Date
2016
Published By
SAE - SAE International
Latest
SAE J1861-2016
Scope
This SAE Recommended Practice establishes minimum tolerance requirements for pilot operated and mechanically actuated modulating type valves@ and through type valves used in the service brake control system when tested in accordance with the test procedure outlined in SAE J1859. This document applies to the nominal input-output characteristics as specified by vehicle original equipment manufacturer and labeled by the valve manufacturer as outlined in SAE J1860. The tolerance requirements will include: a. Crack (opening) pressure or force. Crack pressure may be measured at the initial output pressure or as the pressure differential before output pressure exceeds 14 kPa (2 psi). Crack force may be measured at initial output pressure or before output pressure exceeds 14 kPa (2 psi). b. Pressure differential (input-output) Purpose This document establishes uniform tolerance requirements for specified nominal input-output characteristics of pneumatic valves designed to operate at 931 kPa (135 psi) nominal pressure in commercial air braked vehicles. This serves as a supplement to SAE J1410.

SAE J1861-2016 history

  • 2016 SAE J1861-2016 Air Brake Valve Input-Output Characteristic Requirements
  • 2011 SAE J1861-2011 Air Brake Valve Input-Output Characteristic Requirements
  • 2007 SAE J1861-2007 Air Brake Valve Input-Output Characteristic Requirements
  • 2001 SAE J1861-2001 Air Brake Valve Input-Output Characteristic Requirements
  • 1994 SAE J1861-1994 Air Brake Valve Input-Output Characteristic Requirements R(2001)
Air Brake Valve Input-Output Characteristic Requirements



Copyright ©2024 All Rights Reserved