BS ISO 12219-10:2021 Interior air of road vehicles - Whole vehicle test chamber. Specification and methods for the determination of volatile organic compounds in cabin interiors — Trucks and buses
1 Scope
This document describes and specifies the whole vehicle test chamber, the vapour sampling
assembly and the operating conditions for the determination of volatile organic compounds
(VOCs; for more information see Annex E), and carbonyl compounds in vehicle cabin air. There are three measurements performed: one (for VOCs and carbonyl compounds ) during the simulation of ambient conditions ( ambient mode ) at standard conditions of 23 °C with no air exchange; a second only for the measurement
of formaldehyde at elevated temperatures ( parking mode ); and a third for VOCs and carbonyl compounds simulating driving after the vehicle has been parked in the sun starting at elevated
temperatures ( driving mode ). For the simulation of the mean sun irradiation, fixed irradiation in the whole
vehicle test chamber is employed.
The VOC method is valid for measurement of non-polar and slightly polar VOCs in a
concentration range of sub-micrograms per cubic metre up to several milligrams per
cubic metre. Using the principles described in this method, some semi-volatile organic
compounds (SVOC) can also be analysed. Compatible compounds are those which can be
trapped and released from the Tenax TA ® 1 sorbent tubes described in ISO 16000‑6, which includes VOCs ranging in volatility from n -C6 to n -C16.
The sampling and analysis procedure for formaldehyde and other carbonyl compounds is performed by collecting air on to cartridges coated with 2,4-dinitrophenylhydrazine
(DNPH) and subsequent analysis by high performa...
BS ISO 12219-10:2021 history
2022BS ISO 12219-10:2021 Interior air of road vehicles - Whole vehicle test chamber. Specification and methods for the determination of volatile organic compounds in cabin interiors — Trucks and buses