1 Scope
This part of IEC 60068 gives a method of test which provides a standard procedure to determine the ability
of components, equipments or their constituent materials, hereinafter referred to
as specimen, to withstand accidental contact with fluids, without being unacceptably
affected.
The fluids listed in this part of IEC 60068 are representative of those commonly encountered in operational applications. It
is not intended that a specimen should be exposed to all, or even any of them. Nor
is the list intended to be complete; fluids not listed and for which a test is appropriate
should be included in the relevant specification. Guidance is given in annex A on the choice of test fluids, specimens and severities.
These tests are not intended to demonstrate the suitability of components or equipments
to perform in continuous contact with a fluid, e.g. an immersed fuel pump. Nor are
they a test to demonstrate immunity from electrolytic corrosion.