1 Scope
This document specifies the common requirements and test methods, as well as the classification,
marking and energy labelling of gas‑fired central heating boilers that are fitted with atmospheric burners, fan assisted atmospheric burners or fully
premixed burners, and are hereafter referred to as “ boilers ”.
This document is to be used in conjunction with the specific Parts 2 (Part 2‑1, Part 2‑2
and following ones).
This document applies to boilers of types B and C:
NOTE For further background information on appliance types see EN 1749:2020.
a) that use one or more combustible gases of the three gas families at the pressures
stated in EN 437:2021;
b) where the temperature of the water does not exceed 105 °C during normal operation;
c) where the maximum operating pressure in the water circuit does not exceed 6 bar;
d) which can give rise to condensation under certain circumstances;
e) which are declared in the instructions for installation to be either a "condensing"