CNS 4765-1986
Scope
This standard stipulates that after placing a molybdenum-containing Worthfield iron-based stainless steel test piece in a 10% nitric acid-3% hydrofluoric acid solution at 70°C, the corrosion loss is measured compared with the corrosion degree of the reprocessed sample. A test method to evaluate the degree of grain boundary corrosion.
CNS 4765-1986 history
1986CNS 4765-1986 Method of Nitric-Hydrofluoric Acid Test for Stainless Steels