YD/T 4964-2024
BGPsec Technical Requirements BGPsec Protocol (English Version)

Standard No.
YD/T 4964-2024
Language
Chinese, Available in English version
Release Date
2024
Published By
Professional Standard - Post and Telecommunication  CN  /  YD
Latest
YD/T 4964-2024
 

Introduction

Analysis of BGPsec Core Security Mechanism

BGPsec achieves three major security guarantees through digital signature chain:

Security dimension Traditional BGP BGPsec enhancement
Path verification No encryption verification Each AS generates ECDSA signature
Source authorization Depends on IP prefix announcement Requires matching RPKI's ROA authorization
Anti-tampering AS_PATH can be forged Secure_Path is protected by hashing

Key technology implementation of the protocol

1. BGPsec_PATH attribute structure

Contains two core components:

  • Secure Path: records AS path information, each segment contains a 4-byte AS number, pCount repeat count and Confed_Segment alliance identifier
  • Signature Block: stores elliptic curve signatures (default P-256 curve), each signature segment contains a 20-byte SKI and a variable-length signature value

Typical application scenario example

When AS64500 announces the route to AS64501:

  1. Hash the (prefix + target AS number + path history) using the RPKI certificate private key
  2. Generate ECDSA signature and encapsulate it into Signature Segment
  3. Combine Secure Path segment and signature segment to form BGPsec_PATH attribute

In-depth analysis of verification algorithm

The receiver verification process adopts reverse chain verification:

Steps Operation Failure handling
1 Check syntax structure and AS number continuity Immediately discard malformed messages
2 Query certificate public key from RPKI cache Mark as "invalid" status
3 Verify the validity of the signature hop by hop Terminate the current signature block verification

Deployment Implementation Recommendations

1. Incremental Deployment Strategy

  • Transition period: Maintain both the old and new algorithm signature blocks (RFC 8208 regulations)
  • Confederation network: Configure Confed_Segment flag processing rules
  • Routing server: Set pCount=0 to avoid path expansion

2. Key points of operation and maintenance

  1. Ensure that the RPKI cache synchronization cycle is ≤1 hour
  2. Monitor the success rate of Signature Block verification
  3. Configure pCount processing rules during AS migration

Comparative analysis of security enhancements

Attack Type Traditional BGP BGPsec Protection
Route Hijacking High Risk Need to break through ECDSA signature
Path Shortening Common pCount=0 requires explicit configuration
Replay Attack Undetectable Defense through Nonce Mechanism

YD/T 4964-2024 history

BGPsec Technical Requirements BGPsec Protocol

Standard and Specification

IEC 60364-5-53:2001/AMD1:2002 Electrical installations of buildings - Part 5-53: Selection and erection of electrical equipment; Isolation, switching and control; Amendment 1 IEC 60364-5-55:2011+AMD1:2012 CSV Electrical installations of buildings - Part 5-55: Selection and erection of electrical equipment - Other equipment DIN IEC 60364-5-52 E:2004-07 Information technology software product evaluation methods Part 3: Quality characteristics GB 16895.6-2000 Electric installations of buildings-Part 5: Selection and erection of electrical equipment-Chapter 52: Wiring systems VDE 0100-560 E*DIN VDE 0100-560:2007-12 Low-voltage electrical installations – Part 5-56: Selection and erection of electrical equipment – Safety services IEC 60364-5-57:2022 Low-voltage electrical installations - Part 5-57: Selection and erection of electrical equipment - Erection of stationary secondary batteries IEC 60364-5-55:2011+AMD1:2012+AMD2:2016 CSV Electrical installations of buildings - Part 5-55: Selection and erection of electrical equipment - Other equipment VDE 0100-520-1 E*DIN VDE 0100-520-1:2019-11 Low-voltage electrical installations - Part 5-52: Selection and erection of electrical equipment — Wiring systems VDE 0100-530 E*DIN VDE 0100-530:2010-04 Erection of low voltage installations - Selection and erection of electrical equipment - Part 530: Switchgear and controlgear IEC TR2 61200-53/COR1:1995 Electrical installation guide - Part 53: Selection and erection of electrical equipment - Switchgear and controlgear