| Relay type | Working characteristics | Typical model | Working value range |
|---|---|---|---|
| Poleless relay | Independent of current direction | JWXC-1000 | 12-16V |
| Pole relay | Depends on current direction | JYXC-270 | 8-12V |
| Biased relay | Unidirectional action | JPXC-1000 | 10-14V |
The standard stipulates that the relay should work reliably in the temperature range of -40℃~+60℃ and below 3000 meters above sea level (air pressure ≥70.1kPa), among which:
Electrical parameters need to be converted according to standard formulas:
Voltage conversion: Ut=U20[1+α(t-20)] (Copper α=0.0041/℃)
Resistance conversion: R20=Rt/[1+α(t-20)]
| Type | Mechanical life | Electrical life |
|---|---|---|
| Normal contact without pole | 107 times | 5×105 times |
| Reinforced contact with pole | 2×103 times | 1×104 times |

Copyright ©2026 All Rights Reserved
Update:
Tue, 14 Jul 2026 03:32:15 +0000