| Technical dimension | Traditional granary | Air-film reinforced concrete silo |
|---|---|---|
| Structural form | Brick-concrete/steel structure | Air-film formwork + reinforced concrete thin shell |
| Single silo capacity | ≤5000t | ≤10000t |
| Air tightness standard | 500Pa/300s | 500Pa/1200s |
According to Article 6.3.2, the foundation deformation control value must meet the following requirements:
- Average settlement ≤200mm
- Inclination ≤0.004
The structural safety level is designed as Level 2, and the seismic fortification category is Class C.
The air film silo inlet and outlet system should be arranged symmetrically:
- The high-level release port is ≥5m from the ground
- The low-level release port is ≥0.8m from the ground
The ventilation system must meet the requirements of LS/T 1202, Technical Code for Ventilation of Grain Storage Machinery.
Load combinations to be considered:
- Uneven additional load of shotcrete (≥0.75kN/m²)
- Grain load partial factor 1.3
Stability verification safety factor is 6.6 (Article 6.4.4)