GB/T 43685-2024
General technical requirements for inflatable membrane structure cabins and controlled environments (English Version)

Standard No.
GB/T 43685-2024
Language
Chinese, Available in English version
Release Date
2024
Published By
General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China  CN  /  GB
Latest
GB/T 43685-2024
 

Introduction

1. Standard Overview

GB/T 43685-2024 "General Technical Requirements for Inflatable Membrane Structure Cabins and Controlled Environments" specifies the technical requirements, test methods, and packaging, labeling, transportation and storage requirements for inflatable membrane structure cabins. It is applicable to emergency applications of inflatable membrane structure cabins and controlled environments that use air as a support system.


2. Technical Framework of the Standard

Chapter Number Overview Core Requirements
1 Scope Definition of the scope of application and technical fields
2 Normative References Related Standards and Technical Requirements
3 Terms and Definitions Explanation of Key Terms
4 Requirements Technical Indicators, Performance Parameters and Test Methods
5 Packaging, labeling, transportation and storage Product protection and management requirements

3. Interpretation of core technical indicators

4.2.1 The inflatable membrane structure cabin should meet the basic requirements of ISO5 cleanliness and secondary biosafety experiment.

4.2.4 The deployment time is ≤12 hours, and the withdrawal time is ≤12 hours to meet the needs of rapid deployment.

4.5.1 The performance parameters of the membrane material include thickness, tensile strength, tear strength, etc. to ensure the stability of the structure.


4. Application Scenarios and Implementation Suggestions

Application Scenario Comparison Table

Functional Requirements Suggested Cabin Combination Remarks
Medical Testing Laboratory ≥3 units/set Must meet biosafety requirements
Reagent Production Workshop ≥7 units/set High cleanliness requirement
Isolation Ward ≥2 units/set Priority for emergency deployment

Implementation suggestions

1. Before deployment, the site needs to be evaluated to ensure that it meets the site selection requirements (geological, meteorological and other conditions).

2. Select the appropriate number and configuration of cabins according to the application scenario, and refer to the integration suggestions in Appendix C.

3. After installation, trial operation and acceptance are required to ensure system stability and performance meet the standards.

GB/T 43685-2024 Referenced Document

  • GB 2894 Safety Colors and Safety Signs*2025-05-30 Update
  • GB 50009 Load code for the design of building structures
  • GB 50073 Code for design of clean room
  • GB 50243 Code for acceptance of construction quality of ventilation and air conditioning engineering
  • GB 50346 Architectural and technical code for biosafety laboratories
  • GB 51039 General Hospital Building Design Code
  • GB 55037 General code for building fire protection
  • GB/T 19411 Dehumidifier*2024-10-26 Update
  • GB/T 30161 Coated fabrics for membrane structures
  • GB/T 7725 Room air conditioner
  • JB/T 7258 Centrifugal blower for general purpose*2025-04-10 Update

GB/T 43685-2024 history

  • 2024 GB/T 43685-2024 General technical requirements for inflatable membrane structure cabins and controlled environments
General technical requirements for inflatable membrane structure cabins and controlled environments

Topics on standards and specifications

Standard and Specification




Copyright ©2026 All Rights Reserved
Update: Sun, 01 Mar 2026 19:14:24 +0000