Analysis of the core content of the standard
| Comparison dimensions | Bonded type (Type I) | Non-bonded type (Type II) |
| Structural characteristics | Fusion/bonded integral pipe wall | Layered structure can be relatively displaced |
| Typical pressure level (MPa) | 10-30 | 16-32 |
| Minimum bending radius (mm) | 950-1150 | 800-1150 |
| Applicable scenarios | High pressure stable working conditions | Frequent bending scenarios |
Detailed explanation of key technical indicators
1. Material system requirements
The standard clearly classifies lining layer materials:
- PE material: Must reach PE80 or PE100 grade (GB/T 18475)
- PEX material: Meets the requirements of GB/T 18992.2 cross-linked polyethylene
- Acidic gas environment: Additional test of H2S/CO2 permeability (Appendix B) is required
2. Core performance parameters
Key points for implementation of the standard
1. Inspection rules
Factory inspection shall include 7 major items:
- Appearance quality (visual inspection)
- Dimensional accuracy (GB/T 8806)
- Bursting pressure test
- Tensile performance verification
- Conductor resistance test
- Insulation resistance test
- Whole roll pressure test (1h NPR pressure)
2. Installation specifications
Key control points:
- Bending radius: always greater than MBR (minimum bending radius)
- Lowering speed: 5-8m/min, reduced to 1-5m/min when the suspended weight is abnormal
- Electrical performance monitoring: test the cable insulation resistance every 500m
- Pressure balance: fill the pipe with clean water before lowering to prevent crushing
Technical evolution background
Compared with industry specifications such as SY/T 6662.2, this standard has three major breakthroughs:
- Cable integration standardization: for the first time, the integration technical requirements of power cables, signal cables and auxiliary heating cables are clarified
- Material system expansion: New applicable specifications for high-performance polymers such as PVDF and PA
- Intelligent monitoring support: The integrated solution of supporting optical fiber (GB/T 9771.1) lays the foundation for digital oil fields