GA 1766-2021
Acceptance specification for public security video image information system (English Version)

Standard No.
GA 1766-2021
Language
Chinese, Available in English version
Release Date
2021
Published By
Professional Standard - Public Safety Standards  CN  /  GA
Latest
GA 1766-2021
Replace
GA 793.3-2008
 

Introduction

Standard Evolution and Core Changes

Dimensions 2008 Edition (GA 793.3) 202X New Edition Impact of Changes
Acceptance Scope Urban Monitoring and Alarm Networking System Public Security Video Image Information System Expanded to all police video application scenarios
Technical Indicators Includes 6 types of subsystem acceptance Focus on core function acceptance Delete overly detailed technical terms
Acceptance Process Three-level acceptance system Three dimensions of construction/technology/data Strengthen process traceability

Analysis of key acceptance factors

Core indicators for construction acceptance

The new standard requires that the installation firmness inspection pass rate of front-end equipment be ≥80%, the lightning protection grounding resistance value be ≤4Ω, and the cable identification completeness rate be 100%. A case study of a local public security bureau shows that the use of intelligent inspection instruments can improve construction acceptance efficiency by 40%...

Required inspection items for technical acceptance

  • Cascade function: must comply with GB/T 28181 standard, measured transmission delay ≤2s
  • Video storage: minimum storage period of 180 days, support for SVAC/H.265 dual encoding
  • Clock synchronization: server deviation ≤1s, acquisition equipment ≤3s

Implementation suggestions

Acceptance preparation stage

  1. Complete the system trial operation 30 days in advance and record abnormal events
  2. Prepare 14 types of original acceptance materials (including hidden engineering image materials)
  3. Configure professional testing equipment such as network analyzer

Common Problem Solving

When the acceptance rate is between 0.6-0.8, it is recommended to: ①Prioritize rectification of Class A mandatory inspection items ②Supplement third-party inspection reports ③Extend the trial operation period by 15 days...

GA 1766-2021 Referenced Document

  • GA 308 Acceptance check criterion of security and alarm systems
  • GB 50348-2018 Safety engineering technical standards
  • GB/T 28181 Technical requirements for information transmission,switch and control in video surveillance networking system for public security*2022-12-30 Update

GA 1766-2021 history

  • 2021 GA 1766-2021 Acceptance specification for public security video image information system
  • 2008 GA 793.3-2008 Conformity assessment of city area monitoring and alarming network system.Part 3:Acceptance specification of system

GA 1766-2021 Acceptance specification for public security video image information system has been changed from GA 793.3-2008 Conformity assessment of city area monitoring and alarming network system.Part 3:Acceptance specification of system.

Acceptance specification for public security video image information system

Topics on standards and specifications

Standard and Specification




Copyright ©2026 All Rights Reserved
Update: Thu, 05 Feb 2026 04:53:10 +0000