This standard establishes a unified method for testing the electrical characteristics of flexible micro-electromechanical devices (MEMS) under cyclic bending loads, focusing on solving the reliability assessment problems of products such as flexible sensors and foldable electronic devices. The performance degradation law of the device is visualized through the three-dimensional PSN curve (performance-bending severity-number of cycles).
| Test elements | IEC 62047-35(static bending) | IEC 62047-43(cyclic bending) |
|---|---|---|
| Test purpose | Single bending limit assessment | Performance degradation law under cyclic load |
| Core parameters | Minimum folding distance dmin | Folding distance range (dmin-dmax) |
| Data presentation | PS two-dimensional curve | Three-dimensional PSN surface |
| Test cycle | Single loading | ≥104 cycles |
The test device must meet the following requirements: Loading wall parallelism error < specimen thickness, surface roughness <0.1 times thickness, displacement measurement accuracy is controlled according to the folding distance:
Recommended rectangular specimen size: length 1-300mm, thickness 10μm-1mm. It is necessary to ensure that the functional area is located at the center line of the specimen, and the bending axis direction should include two orientation tests of 0° and 90°.
Through multiple groups of different dmin/dmax combination tests, the surface of performance parameters (resistance/capacitance, etc.) changing with bending severity and number of cycles is plotted:
Typical termination condition: performance decays to 10% of the initial value or 106 cycles are completed.
It is recommended to conduct multi-axis cyclic testing in the early stage of flexible circuit design to identify brittle interconnection parts. The example case shows that the resistance of a 0.2mm silver wire increases by 40% after 2000 cycles at a folding distance of 30mm.
Must include: bending direction/position diagram, specimen size (key length parameter), three-dimensional performance degradation curve, test conditions (temperature and humidity/load frequency). It is recommended to add a two-dimensional cross-section diagram to enhance data readability.
With the surge in demand for flexible sensors in the Internet of Things, the traditional static bending test (IEC 62047-35) can no longer meet the actual working condition evaluation. The PSN method of this standard innovatively solves the following problems: multi-level load coupling effect evaluation, special testing requirements for foldable equipment and so on, providing the industry with a unified reliability verification framework.