The third edition (2024) of this standard replaces the 2013 edition. The main technical changes include:
Applicable to evaluating the mechanical reliability of cable fixing structures of fiber optic interconnects and passive components under axial pressure.
| Components | Technical requirements | Typical parameters |
|---|---|---|
| Mobile fixture | Clamping length ≥ 3 times cable diameter | Clamping force does not damage the cable body |
| Fixed fixture | Does not change the mechanical properties of the device | Rigid fixed reference surface |
| Force application device | Smooth loading capacity | Rate≤50N/s |
Select test load according to cable diameter:
Test duration is at least 2 minutes, recovery time ≥4 hours
Compared with the 2013 version, the 2024 version places more emphasis on the test applicability of structures without reinforcements, reflecting the industry's trend towards miniaturization. Removing the closure-specific table means unifying the evaluation criteria for various types of devices.