| Parameter Category | 6.3mm Terminal | 2.8mm Signal Terminal |
|---|---|---|
| Maximum Tensile Load | 25NVertical Force | Requires Compatibility with Auxiliary Contacts |
| Plating Requirements | Silver Plating | 6-12μmGold Plating |
| Mass Limitation | Conical Barrel Version ≤19g, Nut Version ≤20g | |
The polarized signal contact uses a commercial-grade diode (military environment must comply with MIL-PRF-19500), with a maximum current of 0.5A at 125°C and a peak withstand voltage of 800V. The main contact and the signal contact are in an inverse logic relationship:
The voltage drop test shows that the maximum voltage drop is only 0.2V at a rated current of 25A, but the 100mA low current test requires a voltage drop of ≤2.5mV to ensure the accuracy of micro-current detection.
| Test items | Ground conditions | 15,000 meters altitude |
|---|---|---|
| Dielectric strength | 1,500V | 400V |
| Vibration test | 10g sine vibration +5.8Grms random vibration at 70°C | |
| Short circuit breaking | 4,000A(28VDC) | 1,100A(115VAC) |
1. Note when Panel installation:
2. Signal contact usage restrictions:
This standard is mainly upgraded compared with the previous version: