IEC 61010-031:2015
Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test

Standard No.
IEC 61010-031:2015
Release Date
2015
Published By
International Electrotechnical Commission (IEC)
Status
 2018-06
Replace By
IEC 61010-031:2018
Latest
IEC 61010-031:2022 CMV
Replace
IEC 66/569/FDIS:2015 IEC 61010-031:2002 IEC 61010-031 AMD 1:2008 IEC 61010-031 Edition 1.1:2008
Scope
Probe assemblies included in scope This part of IEC 61010 specifies safety requirements for hand-held and hand-manipulated probe assemblies of the types described below@ and their related accessories. These probe assemblies are for direct electrical connection between a part and electrical test and measurement equipment. They may be fixed to the equipment or be detachable accessories for the equipment. a) Type A: low-voltage and high-voltage@ non-attenuating probe assemblies. Non-attenuating probe assemblies that are RATED for direct connection to voltages exceeding 30 V r.m.s.@ 42@4 V peak@ or 60 V d.c.@ but not exceeding 63 kV. They do not incorporate components which are intended to provide a voltage divider function or a signal conditioning function@ but they may contain non-attenuating components such as fuses (see Figure 1.) b) Type B: high-voltage attenuating or divider probe assemblies. Attenuating or divider probe assemblies that are RATED for direct connection to secondary voltages exceeding 1 kV r.m.s. or 1@5 kV d.c. but not exceeding 63 kV r.m.s. or d.c. The divider function may be carried out wholly within the probe assembly@ or partly within the test or measurement equipment to be used with the probe assembly (see Figure 2). c) Type C: low-voltage attenuating or divider probe assemblies. Attenuating or divider probe assemblies for direct connection to voltages not exceeding 1 kV r.m.s. or 1@5 kV d.c. The signal conditioning function may be carried out wholly within the probe assembly@ or partly within the test or measurement equipment intended to be used with the probe assembly (see Figure 3). d) Type D: low-voltage attenuating@ non-attenuating or other signal conditioning probe assemblies@ that are RATED for direct connection only to voltages not exceeding 30 V r.m.s.@ or 42@4 V peak@ or 60 V d.c.@ and are suitable for currents exceeding 8 A (see Figure 4). Probe assemblies excluded from scope This standard does not apply to current sensors within the scope of IEC 61010-2-032 (Handheld and hand-manipulated current sensors)@ but may apply to their input measuring circuit leads and accessories. Object Aspects included in scope The purpose of the requirements of this standard is to ensure that HAZARDS to the OPERATOR and the surrounding area are reduced to a tolerable level. Requirements for protection against particular types of HAZARDS are given in Clauses 6 to 13@ as follows: a) electric shock or burn (see Clauses 6@ 10 and 11); b) mechanical HAZARDS (see Clauses 7@ 8 and 11); c) excessive temperature (see Clause 9); d) spread of fire from the probe assembly (see Clause 9); e) arc flash (see Clause 13). Additional requirements for probe assemblies which are designed to be powered from a lowvoltage mains supply@ or include other features not specifically addressed in this standard are in other parts of IEC 61010. NOTE Attention is drawn to the possible existence of additional requirements regarding the health and safety of labour forces. Aspects excluded from scope This standard does not cover: a) reliable function@ performance@ or other properties of the probe assembly; b) effectiveness of transport packaging.

IEC 61010-031:2015 Referenced Document

  • IEC 60027-1:1992 Letter symbols to be used in electrical technology; part 1: general
  • IEC 60027-2:2005 Letter symbols to be used in electrical technology - Part 2: Telecommunications and electronics
  • IEC 60027-3:2002 Letter symbols to be used in electrical technology - Part 3: Logarithmic and related quantities, and their units
  • IEC 60027-4:2006 Letter symbols to be used in electrical technology - Part 4: Rotating electric machines
  • IEC 60027-6:2006 Letter symbols to be used in electrical technology - Part 6: Control technology
  • IEC 60027-7:2010 Letter symbols to be used in electrical technology - Part 7: Power generation, transmission and distribution
  • IEC 60529:1989 Degrees of protection provided by enclosures (IP code)
  • IEC 61010-1:2010 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
  • IEC 61180-1:1992 High-voltage test techniques for low-voltage equipment; part 1: definitions, test and procedure requirements
  • IEC Guide 104:2010 The preparation of safety publications and the use of basic safety publications and group safety publications (Edition 4.0)

IEC 61010-031:2015 history

  • 0000 IEC 61010-031:2022 CMV
  • 2018 IEC 61010-031:2015/AMD1:2018/COR1:2018 Corrigendum 1 - Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement
  • 2018 IEC 61010-031:2018 Safety requirements for electrical equipment for measurement@ control and laboratory use – Part 031: Safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement (Edition 2.1; Consolidated Reprint)
  • 0000 IEC 61010-031:2015 RLV
  • 2008 IEC 61010-031:2002/AMD1:2008 AMENDEMENT 1 - Règles de sécurité pour appareils électriques de mesurage@ de régulation et de laboratoire – Partie 031: Prescriptions de sécurité pour sondes équipées tenues à la main pour mesurage et essais électriques (Edition 1.0)
  • 2008 IEC 61010-031:2008 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test
  • 2002 IEC 61010-031:2002 Safety Requirements for Electrical Equipment for Measurement@ Control@ and Laboratory Use - Part 031: Safety Requirements for Hand-Held Probe Assemblies for Electrical Measurement and Test (Edition 1.0)



Copyright ©2024 All Rights Reserved