DS/EN 60695-2-13:2011
Fire hazard testing - Part 2-13: Glowing/hot-wire based test methods - Glow-wire ignition temperature (GWIT) test method for materials

Standard No.
DS/EN 60695-2-13:2011
Release Date
2011
Published By
Danish Standards Foundation
Status
Latest
DS/EN 60695-2-13:2011
Replace By
DIN ISO 20369:2012
Replace
DS/EN 60695-2-13-2001
Scope
This parts of IEC 60695 specifies the details of the glow-wire test to be applied to test specimens of solid electrical insulating materials or other solid materials for ignitability testing to determine the glow-wire ignition temperature (GWIT).The GWIT is the temperature which is 25 K (or 30 K) higher than the maximum test temperature, determined during this standardized procedure, at which the tested materiala) does not ignite, or b) if sustained and continuous flaming combustion does not occur for a time longer than 5 s for any single flame event and the specimen is not totally consumed. This test is a materials test carried out on a series of standard

DS/EN 60695-2-13:2011 history

  • 2021 DS/EN IEC 60695-2-13:2021 Fire hazard testing – Part 2-13: Glowing/hot-wire based test methods – Glow-wire ignition temperature (GWIT) test method for materials