BS 7870-3.50:2011
LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated, copper wire waveform or helical concentric cables with solid aluminium conductors, havi

Standard No.
BS 7870-3.50:2011
Release Date
2011
Published By
British Standards Institution (BSI)
Status
Replace By
BS 7870-3.50:2011(2012)
Latest
BS 7870-3.50:2023
Replace
BS 7870-3.50:2005
 

Scope
This section of BS 7870 specifies requirements for the construcion,dimensions and mechanical and electrical properties of XLPE insulated,concentric copper wire screened waveform or helical cables with solid aluminium core conductors having a rated voltage of 0.6/1(1.2)kV.It is applicable to cables that,when assessed by the specified tests,produce lower levels of smoke and corrosive gases under exposure to fire than cables conforming to BS 7870-3.11 or to BS 7870-3.40. It specifies requirements for the following types of cable: a) 3-core,3-phase,with XLPE insulaiton,a concentric neutral/earth conductor of copper wires on a synthetic bedding and a thermoplastic oversheath; b) 4-core,3-phase and a separate neutral,with XLPE insulaiton,a concentric earth conductor of copper wires on a synthetic bedding, and a thermoplastic oversheath. This section of BS 7870 is applicable to cables that are designed for a maximum continuous conductor operating temperature of 80℃ and for a maximum short circuit conductor temperature of 250℃.

BS 7870-3.50:2011 Referenced Document

  • BS 7870-1 LV and MV polymeric insulated cables for use by distribution and generation utilities Part 1 : General*2025-05-02 Update
  • BS 7870-2  LV and MV polymeric insulated cables for use by distribution and generation utilities. Methods of test (Implementation of HD 605 S3:2019)*2022-11-30 Update
  • BS EN 50267-2-1 Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Procedures - Determination of the amount of halogen acid gas - Determination of the amount of halogen acid gas
  • BS EN 60228 Conductors of insulated cables
  • BS EN 60811-1-2 Common test methods for insulating and sheathing materials of electric and optical cables — Part 1 - 2 : General application — Thermal ageing methods
  • BS EN 60811-1-3 Insulating and sheathing materials of electric and optical cables — Common test methods — Part 1 - 3 : General application — Methods for determining the density — Water absorption tests — Shrinkage test
  • BS EN 61034-1 Measurement of smoke density of cables burning under defined conditions. Test apparatus
  • BS EN 61034-2 Measurement of smoke density of cables burning under defined conditions - Test procedure and requirements*2020-03-31 Update

BS 7870-3.50:2011 history

  • 2023 BS 7870-3.50:2023 Tracked Changes. LV and MV polymeric insulated cables for use by distribution and generation utilities. Distribution cables of rated voltage 0.6/1(1.2) kV. Specification. XLPE insulated, copper wire waveform or helical concentric cables with solid
  • 0000 BS 7870-3.50:2011(2012)
  • 2011 BS 7870-3.50:2011 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated, copper wire waveform or helical concentric cables with solid aluminium conductors, havi
  • 2005 BS 7870-3.50:2005 LV and MV polymeric insulated cables for use by distribution and generation utilities - Specification for distribution cables of rated voltage 0.6/1 kV - XLPE insulated, copper wire waveform or helical concentric cables with solid aluminium conductors, ha

Standard and Specification

BS 7870-3.40:2023 Tracked Changes. LV and MV polymeric insulated cables for use by distribution and generation utilities. Distribution cables of rated voltage 0.6/1 (1.2) kV BS 7870-3.50:2023 Tracked Changes. LV and MV polymeric insulated cables for use by distribution and generation utilities. Distribution cables of rated voltage 0.6/1(1.2) kV BS 7870-3.40:2011 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV. XLPE BS 7870-3.11:2011 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV. XLPE AS/NZS 1660.1:1998 Test Methods for Electric Cables, Cords and Conductors Method 1: Conductors and Metallic Components BS 7870-3.21:2011 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV. XLPE JIS C 3667:2008 Power cables with extruded insulation and their accessories for rated voltages from 1 kV up to 30 kV -- Cables for rated voltages of 0.6/1 kV BS 7870-3.12:2011 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV. XLPE GSO IEC 60055-2:2017 Paper-insulated metal-sheathed cables for rated voltages up to 18/30 kV (with copper or aluminium conductors and excluding gas-pressure and oil-filled cables