LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated split concentric cables with copper or aluminium conductors, having low emission of smok

Standard No.
BS 7870-3.22:2011
Release Date
2011
Published By
British Standards Institution (BSI)
Status
Replace By
BS 7870-3.22:2011(2012)
Latest
BS 7870-3.22:2011(2012)
 

Scope
This section of BS 7870 specifies requirements for the construcion,dimensions and mechanical and electrical properties of split concentric service calbes having a rated voltage of 0.6/1(1.2)kV.It is applicable to cables that,when assessed by the specified tests,produce lower levels of smoke and corrosive gases under exposure to fire than cables conforming to BS 7870-3.21. It specifies requirements for the following types of cable: a) single phase or 3-phase; b) stranded copper or solid aluminium conductors; c) XLPE insulation and PVC oversheath. This section of BS 7870 is applicable to cables that are designed for a maximum continuous conductor operating temperature of 90℃ and for a maximum short circuit conductor temperature of 250℃.

BS 7870-3.22:2011 Referenced Document

  • BS 7870-1 LV and MV polymeric insulated cables for use by distribution and generation utilities Part 1 : General*2025-05-02 Update
  • BS 7870-2  LV and MV polymeric insulated cables for use by distribution and generation utilities. Methods of test (Implementation of HD 605 S3:2019)*2022-11-30 Update
  • BS EN 50267-2-1 Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Procedures - Determination of the amount of halogen acid gas - Determination of the amount of halogen acid gas
  • BS EN 60228 Conductors of insulated cables
  • BS EN 60811-1-1 PDF Processing Technical Specifications
  • BS EN 60811-1-2 Common test methods for insulating and sheathing materials of electric and optical cables — Part 1 - 2 : General application — Thermal ageing methods
  • BS EN 60811-1-3 Insulating and sheathing materials of electric and optical cables — Common test methods — Part 1 - 3 : General application — Methods for determining the density — Water absorption tests — Shrinkage test
  • BS EN 61034-1 Measurement of smoke density of cables burning under defined conditions. Test apparatus
  • BS EN 61034-2 Measurement of smoke density of cables burning under defined conditions - Test procedure and requirements*2020-03-31 Update

BS 7870-3.22:2011 history

  • 0000 BS 7870-3.22:2011(2012)
  • 2011 BS 7870-3.22:2011 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated split concentric cables with copper or aluminium conductors, having low emission of smok

Standard and Specification

BS 7870-3.50:2023 Tracked Changes. LV and MV polymeric insulated cables for use by distribution and generation utilities. Distribution cables of rated voltage 0.6/1(1.2) kV BS 7870-3.40:2023 Tracked Changes. LV and MV polymeric insulated cables for use by distribution and generation utilities. Distribution cables of rated voltage 0.6/1 (1.2) kV BS 7870-3.21:2011 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV. XLPE BS 7870-3.12:2011(2012 BS 7870-3.12:2011 LV and MV polymeric insulated cables for use by distribution and generation utilities Part 3: Specification for distribution cables of rated AS/NZS 1660.1:1998 Test Methods for Electric Cables, Cords and Conductors Method 1: Conductors and Metallic Components BS 7870-3.11:2011 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV. XLPE BS 7870-3.40:2011 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV. XLPE BS 7870-3.12:2011 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV. XLPE GSO IEC 60055-2:2017 Paper-insulated metal-sheathed cables for rated voltages up to 18/30 kV (with copper or aluminium conductors and excluding gas-pressure and oil-filled cables