YD 5178-2009
Volume Drawing of Manhole and Handhole for Communication Conduit Engineering (English Version)

Standard No.
YD 5178-2009
Language
Chinese, Available in English version
Release Date
2009
Published By
Professional Standard - Post and Telecommunication
Latest
YD 5178-2009
Replace
YD 5039-1997
Scope
This atlas is a professional atlas of manholes and hand holes in communication pipeline engineering construction. This atlas includes standard series of brick manholes and hand holes, concrete block manholes and accessories, etc. This atlas is suitable for new communication pipeline projects. Renovation and expansion of communication pipeline projects should comply with the relevant provisions of this atlas based on local material supply, construction site conditions, environment, municipal requirements, etc. The load capacity of the overlying manhole and handhole is determined based on factors such as the maximum load that may occur at the location where it is installed. The load strength of the manhole ring installed on the overlying manhole should be matched with the overlying load capacity. That is, the load capacity of the mouth ring must be greater than or equal to the overlying load capacity. When the manholes and hand holes exceed the dimensions and usage conditions specified in this atlas, their foundations, walls, and overlying structures should be calculated separately. The dimensions of manhole drawings, hole drawings and accessory drawings in this atlas are all in millimeters.

YD 5178-2009 Referenced Document

  • CJJ 37-1990 Code for design of municipal road
  • GB 50003-2001 Code for design of masonry structures
  • GB 50010-2002 Code for design of concrete structures
  • GB 50203-2002 Code for acceptance of construction quality of masonry engineering
  • GB 50204-2002 Code for acceptance of constructional quality of concrete structures
  • GB 50373-2006 Design code for communication conduit and passage engineering
  • GB 50374-2006 Code of construction and acceptance for communication conduit engineering

YD 5178-2009 history

  • 2009 YD 5039-2009 Provisional Specifications on Enironment Protection for Engineering Construction of Telecommunications
  • 1997 YD 5039-1997 Specifications on Environment Protection for Engineering Construction of Telecommunications

YD 5178-2009 Volume Drawing of Manhole and Handhole for Communication Conduit Engineering has been changed from YD 5039-1997 Specifications on Environment Protection for Engineering Construction of Telecommunications.

Volume Drawing of Manhole and Handhole for Communication Conduit Engineering