IEC 60502-2:2014+AMD1:2024 CSV Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 2: Cables for rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV)
This part of IEC 60502 specifies the construction, dimensions and test requirements for 6 kV to 30 kV extruded solid insulated power cables used in fixed installations such as distribution networks or industrial facilities. When determining the application, it is recommended to consider the possible risk of radial water ingress. This part includes the design of cables claimed to prevent longitudinal water penetration and the related tests. Cables for special installation and use conditions, such as overhead networks, mining industry, nuclear power plants (inside and outside the containment area), and cables used on the seabed or on ships are not included.
IEC 60229:2007 Electric cables - Tests on extruded oversheaths with a special protective function
IEC 60230 Impulse tests on cables and their accessories CONSOLIDATED VERSION
IEC 60287-3-1 Electric cables — Calculation of the current rating — Part 3-1: Operating conditions — Site reference conditions
IEC 60332-1-2 Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame*, 2025-02-28 Update
IEC 60684-2 Flexible insulating sleeving – Part 2: Methods of test*, 2025-01-01 Update
IEC 60754-1 Test on gases evolved during combustion of materials from cables - Part 2: Determination of acidity (by pH measurement) and conductivity*, 2025-05-12 Update
IEC 60754-2 Test on gases evolved during combustion of materials from cables - Part 2: Determination of acidity (by pH measurement) and conductivity*, 2025-05-12 Update
IEC 60754-3 Test on gases evolved during combustion of materials from cables - Part 3: Measurement of low level of halogen content by ion chromatography
IEC 60853-2 Calculation of the cyclic and emergency current rating of cables - Part 2: Cyclic rating of cables greater than 18/30 (36) kV and emergency ratings for cables of all voltages
IEC 60885-3 Electrical test methods for electric cables — Part 3: Test methods for partial discharge measurements on lengths of extruded power cables
IEC 60986 Short-circuit temperature limits of electric cables with rated voltages from 6 kV (U<(Index)m> = 7,2 kV) up to 30 kV (U<(Index)m> = 36 kV)
IEC 61034-2 Measurement of smoke density of cables burning under defined conditions - Part 2: Test procedure and requirements*, 2025-05-12 Update
ISO 48 Rubber, vulcanized or thermoplastic - Determination of hardness (hardness between 10 IRHD and 100 IRHD)
IEC 60502-2:2014+AMD1:2024 CSV history
2024IEC 60502-2:2024 Power cables and their accessories with extruded insulation for rated voltages from 1 kV (Um = 1.2 kV) to 30 kV (Um = 36 kV) Part 2: Power cables and their accessories with rated voltages from 6 kV (Um = 7.2 kV) to 30 kV (Um = 36 kV)
0000 IEC 60502-2:2014/AMD1:2024 CSV
0000 IEC 60502-2:2014 RLV
2005IEC 60502-2:2005 Power cables with extruded insulation and their accessories for rated voltages from 1 kV (U<(Index)m> = 1,2 kV) up to 30 kV (U<(Index)m> = 36 kV) - Part 2: Cables for rated voltages from 6 kV (U<(Index)m> = 7,2 kV) up to 30 kV (U<(Index)m> = 36 kV)
1999IEC 60502-2:1997/COR1:1999 Corrigendum 1 - Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 2: Cables for rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV)
1998IEC 60502-2:1998 Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<(kursiv)U><(Index)m> = 1,2 kV) up to 30 kV (<(kursiv)U><(Index)m> = 36 kV) - Part 2: Cables for rated voltages from 6 kV (<(kursiv)U><(Index)m> = 7,2 kV) up to 30 k
1998IEC 60502-2:1997/AMD1:1998 Amendment 1 - Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 2: Cables for rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV)
1997IEC 60502-2:1997 Power cables with extruded insulation and their accessories for rated voltages from 1 kV (U<(Index)m> = 1,2 kV) up to 30 kV (U<(Index)m> = 36 kV) - Part 2: Cables for rated voltages from 6 kV (U<(Index)m> = 7,2 kV) up to 30 kV (U<(Index)m> = 36 kV)