TSB-143-2007
Fiber Optic Power Meters: Measurement and Application Issues

Standard No.
TSB-143-2007
Release Date
2007
Published By
TIA - Telecommunications Industry Association
Scope
"The proper calibration of an optical power meter requires the verification of two critical parameters: absolute accuracy at a given reference power over a wavelength range and linearity at a given wavelength over a power range. We discuss the key elements involved in determining the uncertainty in the absolute accuracy and the non-linearity of the power response under what are termed ""reference conditions of calibration"". We also discuss the underlying causes of erroneous measurements resulting from each of the three subsystems constituting a power meter: detector element@ collecting optics and electronics."



Copyright ©2024 All Rights Reserved